Kern DE 60K10DL Postal Scale 35kg DE 60K10DL User Manual

Product codes
DE 60K10DL
Page of 37
DE-BA-e-1255 
37 
10  Instant help  
In case of an error in the program process, briefly turn off the balance and 
disconnect from power supply. The weighing process must then be restarted from 
the beginning. 
Help: 
Fault 
Possible cause 
 
 
The displayed weight does not glow. 
  The balance is not switched on. 
 
  The mains supply connection has been 
interrupted (mains cable not plugged 
in/faulty). 
 
  Power supply interrupted. 
 
 
The  displayed  weight  is  permanently 
changing 
  Draught/air movement 
 
  Table/floor vibrations 
 
  The weighing plate is in contact with 
foreign matter. 
  Electromagnetic fields / static charging 
(choose different location/switch off 
interfering device if possible) 
 
 
The weighing value is obviously  
  The display of the balance is not at zero 
wrong 
  Adjustment is no longer correct. 
 
  Great fluctuations in temperature. 
  Electromagnetic fields / static charging 
(choose different location/switch off 
interfering device if possible) 
 
Should other error messages occur, switch balance off and then on again. If the error 
message remains, inform your specialist dealer.