36.6.11.3 WAVSEL = 01
When WAVSEL = 01, the value of TC_CV is incremented from 0 to 0xFFFF. Once 0xFFFF is reached, the value of 
TC_CV is decremented to 0, then re-incremented to 0xFFFF and so on. See 
A trigger such as an external event or a software trigger can modify TC_CV at any time. If a trigger occurs while TC_CV 
is incrementing, TC_CV then decrements. If a trigger is received while TC_CV is decrementing, TC_CV then increments. 
See 
RC Compare cannot be programmed to generate a trigger in this configuration. 
At the same time, RC Compare can stop the counter clock (CPCSTOP = 1) and/or disable the counter clock (CPCDIS = 1).
Figure 36-11.WAVSEL = 01 Without Trigger
Figure 36-12.WAVSEL = 01 With Trigger
Time
Counter Value
R
C
R
B
R
A
TIOB
TIOA
Counter decremented by compare match with 0xFFFF
0xFFFF
Waveform Examples
Time
Counter Value
TIOB
TIOA
Counter decremented by compare match with 0xFFFF
0xFFFF
Waveform Examples
Counter decremented 
by trigger
Counter incremented 
by trigger
R
C
R
B
R
A