Atmel SAM4S Xplained Pro Starter and Evaluation Kit ATSAM4S-XPRO ATSAM4S-XPRO Data Sheet

Product codes
ATSAM4S-XPRO
Page of 1231
293
SAM4S Series [DATASHEET]
Atmel-11100G-ATARM-SAM4S-Datasheet_27-May-14
15.5.4 Real-time Timer Status Register
Name:
RTT_SR
Address:
0x400E143C
Access:
Read-only
• ALMS: Real-time Alarm Status
0: The Real-time Alarm has not occurred since the last read of RTT_SR.
1: The Real-time Alarm occurred since the last read of RTT_SR.
• RTTINC: Prescaler Roll-over Status
0: No prescaler roll-over occurred since the last read of the RTT_SR.
1: Prescaler roll-over occurred since the last read of the RTT_SR.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RTTINC
ALMS