40.7.11 PWM Sync Channels Update Control Register
Name:
PWM_SCUC
Address:
0x40000028
Access:
Read/Write
UPDULOCK: Synchronous Channels Update Unlock
0: No effect
1: If the UPDM field is set to ‘0’ in 
, writing the UPDULOCK bit to ‘1’ triggers the update 
of the period value, the duty-cycle and the dead-time values of synchronous channels at the beginning of the next PWM 
period. If the field UPDM is set to ‘1’ or ‘2’, writing the UPDULOCK bit to ‘1’ triggers only the update of the period value and 
of the dead-time values of synchronous channels.
This bit is automatically reset when the update is done.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
UPDULOCK