Atmel Evaluation Kit AT91SAM9G25-EK AT91SAM9G25-EK Data Sheet

Product codes
AT91SAM9G25-EK
Page of 1165
922
SAM9G25 [DATASHEET]
11032D–ATARM–10-Mar-2014
40.7.13 ADC Overrun Status Register
Name:
ADC_OVER
Address:
0xF804C03C
Access:
Read-only  
• OVREx: Overrun Error x
0 = No overrun error on the corresponding channel since the last read of ADC_OVER.
1 = There has been an overrun error on the corresponding channel since the last read of ADC_OVER.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
OVRE11
OVRE10
OVRE9
OVRE8
7
6
5
4
3
2
1
0
OVRE7
OVRE6
OVRE5
OVRE4
OVRE3
OVRE2
OVRE1
OVRE0