Atmel Xplained Pro Evaluation Kit ATSAMD20-XPRO ATSAMD20-XPRO Data Sheet

Product codes
ATSAMD20-XPRO
Page of 660
621
Atmel | SMART SAM D20 [DATASHEET]
Atmel-42129K–SAM-D20_datasheet–06/2014
35.2
Revision C
35.2.1 NVMCTRL
1 - When the part is secured and EEPROM emulation area configured to 
none, the CRC32 is not executed on the entire flash area but up to the on-
chip flash size minus half a row. Errata reference: 11988
Fix/Workaround:
When using CRC32 on a protected device with EEPROM emulation area 
configured to none, compute the reference CRC32 value to the full chip flash size 
minus half row.
35.2.2 VREG
1 - With default bit and register settings the device does not work as 
specified in STANDBY mode if load current exceeds 100µA. Errata 
reference: 11082
Fix/Workaround:
Set the FORCELDO bit in the VREG register.
35.2.3 Device
1 - The values stored in the NVM software calibration area for the DFLL 
calibration are not valid. Errata reference: 12843
Fix/Workaround:
None.
2 - Clock Failure detection for external OSC does not work in standby mode. 
Errata reference: 12688
Fix/Workaround:
Before entering standby mode, move the CPU clock to an internal RC, disable 
external OSC and disable the Clock Failure detector. Upon CPU wakeup, restart 
external OSC (if it does not start, the failure occurred during standby), enable the 
Clock Failure detector and move the CPU clock to the external OSC.
3 - If APB clock is stopped and GCLK clock is running, APB read access to 
read-synchronized registers will freeze the system. The CPU and the DAP 
AHB-AP are stalled, as a consequence debug operation is impossible. 
Errata reference: 10416
Fix/Workaround:
Do not make read access to read-synchronized registers when APB clock is 
stopped and GCLK is running. To recover from this situation, power cycle the 
device or reset the device using the RESETN pin.