Atmel Xplained Evaluation Board AT32UC3A3-XPLD AT32UC3A3-XPLD Data Sheet

Product codes
AT32UC3A3-XPLD
Page of 1021
147
32072H–AVR32–10/2012
AT32UC3A3
12.9
Fuses Settings
The flash block contains 32 general purpose fuses. These 32 fuses can be found in the Flash
General Purpose Fuse Register Low (FGPFRLO) of the Flash Controller (FLASHC).
Some of the FGPFRLO fuses have defined meanings outside the FLASHC and are described in
this section.
The general purpose fuses are set by a JTAG chip erase.
12.9.1
Flash General Purpose Fuse Register Low (FGPFRLO)
• BODEN: Brown Out Detector Enable
• BODHYST: Brown Out Detector Hystersis
0: The BOD hysteresis is disabled
1:
 
The BOD hysteresis is enabled
• BODLEVEL: Brown Out Detector Trigger Level
This controls the voltage trigger level for the Brown out detector. For value description refer to Electrical Characteristics chapter. 
If the BODLEVEL is set higher than VDDCORE and enabled by fuses, the part will be in constant reset. To recover from this 
situation, apply an external voltage on VDDCORE that is higher than the BOD Trigger level and disable the BOD.
• LOCK, EPFL, BOOTPROT
These are Flash controller fuses and are described in the FLASHC chapter.
12.9.2
Default Fuse Value
The devices are shipped with the FGPFRLO register value: 0xFFF7FFFF:
• GPF31 reserved for future use
Table 12-8.
FGPFRLO Register Description
31
30
29
28
27
26
25
24
GPF31
GPF30
GPF29
BODEN
BODHYST
BODLEVEL[5:4]
23
22
21
20
19
18
17
16
BODLEVEL[3:0]
BOOTPROT
EPFL
15
14
13
12
11
10
9
8
LOCK[15:8]
7
6
5
4
3
2
1
0
LOCK[7:0]
Table 12-9.
BODEN Field Description
BODEN
Description
0x0
Brown Out Detector (BOD) disabled
0x1
BOD enabled, BOD reset enabled
0x2
BOD enabled, BOD reset disabled
0x3
BOD disabled