Atmel Xplained Evaluation Board AT32UC3A3-XPLD AT32UC3A3-XPLD Data Sheet

Product codes
AT32UC3A3-XPLD
Page of 1021
729
32072H–AVR32–10/2012
AT32UC3A3
27.8.3.12
Pipe n Configuration Register 
Register Name:
UPCFGn, n in [0..7]
Access Type:
Read/Write
Offset:
0x0500 + (n * 0x04)
Reset Value:
0x00000000
• INTFRQ: Pipe Interrupt Request Frequency
This field contains the maximum value in millisecond of the polling period for an Interrupt Pipe.
This value has no effect for a non-Interrupt Pipe.
This field is cleared upon sending a USB reset.
• BINTERVAL: bInterval parameter for the Bulk-Out/Ping transaction
This field contains the Ping/Bulk-out period.
If BINTERVAL>0 and PINGEN=1, one PING token is sent every BINTERVAL micro-frame until it is ACKed by the peripheral.
If BINTERVAL=0 and PINGEN=1, multiple consecutive PING token is sent in the same micro-frame until it is ACKed.
If BINTERVAL>0 and PINGEN=0, one OUT token is sent every BINTERVAL micro-frame until it is ACKed by the peripheral.
If BINTERVAL=0 and PINGEN=0, multiple consecutive OUT token is sent in the same micro-frame until it is ACKed.
This value must be in the range from 0 to 255.
• PINGEN: Ping Enable
This bit is relevant for High-speed Bulk-out transaction only (including the control data stage and the control status stage).
Writing a zero to this bit will disable the ping protocol.
Writing a one to this bit will enable the ping mechanism according to the usb 2.0 standard.
This bit is cleared upon sending a USB reset.
• PEPNUM: Pipe Endpoint Number
This field contains the number of the endpoint targeted by the pipe. This value is from 0 to 15.
This field is cleared upon sending a USB reset.
• PTYPE: Pipe Type
This field contains the pipe type.
31
30
29
28
27
26
25
24
INTFRQ/BINTERVAL
23
22
21
20
19
18
17
16
-
-
-
PINGEN
PEPNUM
15
14
13
12
11
10
9
8
-
-
PTYPE
-
AUTOSW
PTOKEN
7
6
5
4
3
2
1
0
-
PSIZE
PBK
ALLOC
-
PTYPE
Pipe Type
0
0
Control