Atmel SAM4L Xplained Pro Starter Kit Atmel ATSAM4L-XSTK ATSAM4L-XSTK Data Sheet

Product codes
ATSAM4L-XSTK
Page of 1204
188
42023E–SAM–07/2013
ATSAM4L8/L4/L2
12.7.13
BOD Level Register
Name:
BOD18/33LEVEL
Access Type: Read/Write
Reset Value:
0x00000000
• RANGE: BOD Threshold Range (available for BOD18 only)
0: The Standard Threshold Range is selected. See 
 for actual voltage levels.
1: The Low Threshold Range is selected. See 
 for actual voltage levels.
Note that any change to the RANGE field of the BOD18LEVEL register should be done with the BOD18 deactivated, this is to 
avoid spurious resets or interrupts.
• VAL: BOD Value
This field sets the triggering voltage threshold for the BOD. See 
 for actual 
voltage levels.
Note that any change to the VAL field of the BOD18/33LEVEL register should be done with the BOD deactivated, this is to avoid 
spurious resets or interrupts.
31
30
29
28
27
26
25
24
RANGE
-
-
-
-
-
-
23
22
21
20
19
18
17
16
-
-
-
-
-
-
-
-
15
14
13
12
11
10
9
8
-
-
-
-
-
-
-
-
7
6
5
4
3
2
1
0
-
-
VAL[5:0]