Maxim Integrated MAX16814 Evaluation Kit MAX16814EVKIT+ MAX16814EVKIT+ Data Sheet

Product codes
MAX16814EVKIT+
Page of 12
MAX16814 Evaluation Kit
Evaluates: 
 MAX
16814
4_ _ _______________________________________________________________________________________
using  the  SYNC  PCB  pad  and  an  external  AC  clock 
signal. Test points are provided for easy access to IC’s 
VCC and SGND.
Enable and UVLO
The  EV  kit  features  two  jumpers  to  enable/disable  U1 
and configure the UVLO. Jumper JU1 enables the EV kit 
when a shunt is installed and a shunt is also installed on 
pins 1-2 of jumper JU2. Removing jumper JU1 disables 
the  EV  kit.  Configuring  jumper  JU2  to  pins  2-3  allows 
an external controller to enable the circuit and also dis-
ables UVLO resistors R1 and R2. Connect the external 
controller to the ENABLE and SGND PCB pads. Refer to 
the  Enable  section  in  the  MAX16814  IC  data  sheet  for 
additional information. See Table 1 for jumper JU1 and 
JU2 settings.
HB LED Current
The EV kit features a jumper to reconfigure the IC current 
sinks on all 4 channels. When inserted, jumper JU3 con-
figures  the  current-sink  limits  to  150mA,  and  removing 
the  jumper  configures  the  current-sink  limits  to  100mA. 
See Table 2 for jumper JU3 settings.
To  reconfigure  the  circuit  for  another  current-sink  
threshold,  replace  resistor  R15  and  use  the  following 
equation to calculate a new value for the desired current:
LED
1500
R15
I
=
where I
LED
 is the desired HB LED current in amps and 
R15  is  the  new  resistor  value  for  obtaining  the  desired 
HB LED current. Remove jumper JU3 when configuring 
for another current-sink level.
Channel 1–Channel 4 Current-Sink Disabling
The  EV  kit  features  jumpers  to  disable  each  channel’s 
OUT_  current  sink.  When  disabling  a  channel,  install 
a  jumper  in  the  channel’s  respective  OUT_  jumper. 
Remove the shunt to use a channel’s OUT_ sink capabil-
ity. See Table 3 for jumper JU4–JU7 settings.
Table_1._Enable_and_UVLO_(JU1,_JU2)
Table_2._HB_LED_Current_(JU3)
Table_3._Disabling_Channel_1–Channel_4_
(JU4–JU7)
*The series-connected HB LED string must be rated no less 
than 150mA.
SHUNT_POSITION
EN_PIN
EV_KIT_
OPERATION
JU1
JU2
Installed
1-2
Connected to 
UVLO R1 and 
R2 divider
Enabled (UVLO 
operating)
Not 
installed
1-2
Connected to 
UVLO R1 and 
R2 divider
Disabled
Not 
installed
2-3
Connected to 
ENABLE PCB 
pad
External controller 
enabled (no on-
board UVLO)
OUT_
JUMPER
SHUNT_
POSITION
CHANNEL_OPERATION
OUT1
JU4
Not 
installed
Channel 1 operational, 
connect an HB LED 
string* to VOUT and 
OUT1
Installed
Channel 1 OUT1 not 
used
OUT2
JU5
Not 
installed
Channel 2 operational, 
connect an HB LED 
string* to VOUT and 
OUT2
Installed
Channel 2 OUT2 not 
used
OUT3
JU6
Not 
installed
Channel 3 operational, 
connect an HB LED 
string* to VOUT and 
OUT3
Installed
Channel 3 OUT3 not 
used
OUT4
JU7
Not 
installed
Channel 4 operational, 
connect an HB LED 
string* to VOUT and 
OUT4
Installed
Channel 4 OUT4 not 
used
SHUNT_
POSITION
SETI_PIN
HB_LED_
CURRENT-SINK_
LIMITS_(mA)
Not installed
Connected to R15
100
Installed
Connected to R15 
and R16
150