Secutech Radio modules ST002013 Data Sheet

Product codes
ST002013
Page of 32
Page 18
 
Security & Electronic Technologies GmbH
 
 
 
SECU-DATA 1700M (TRbF) 
 
Terminal  Signal, function 
1  Plus-pole of power supply (+22 
V … +40 V), 
reverse polarity protection by two 2 diodes,  
igni
tion prevention level “ib“ 
2  Ground line of power supply (0 V) 
3   Connection of the positive pole of the TRbF 
probe 
4   Connection of the negative pole of the TRbF 
probe 
5  Not connected 
6, 7, 8   Relay contacts, passive, for monitoring the sta-
tus of the RF-connection 
7 is the root, for active RF-connection terminals 
6-7 are interconnected, during RF-interruptions 
terminals 7-8 are interconnected. 
Rated switching capacity: 30 V / 500 mA 
 
SECU-DATA 1500C is used as a receiver, for the connections see  section 
SECU-DATA 1500M/1500C on page 15. 
 