Conrad 393903 time 393903 Data Sheet

Product codes
393903
Page of 17
8
 Options for the Staircase Light ing Timer
1. „Activation Time Extension“
If the relay is already activated, another push of the button at the input „SET“ resets the activation duration to the set value.
2. „Early Shut-Down“
If the relay is already activated, another push of the button at the input „SET“ deactivates the relay output at once.
3. „Short Push of the Button: Time Extension, Long Push of the Button (>3s): Immediate Shut-Down“
If the relay is already activated, another short push of the button (<3 s) at the input „SET“ resets the set activation duration.
Long operation of the button (>=3 s) directly switches off the relay output.
<------------------------T1------------------------>
SET
RESET
RELAIS
<------------------------T1------------------------>
RESET
RELAIS
<------------------------T1------------------------>
<----------------------T1----------
SET
  <3s
RESET
<------------------------T1------------------------>
     = 3s
<--------T1------
RELAIS
<------------------------T1------------------------->
SET