Dear customer, thank you for purchasing this power supply unit. 
These installation and operating instructions contain basic instructions and im -
por tant information regarding safety, installation, commissioning and the op-
timal use of the unit. Keep these ope ra ting instructions for future refe rence!
This device left the factory in a perfectly safe condition. In order to maintain 
this condition and ensure safe operation the user must observe the safety instruc-
tions and warnings contained in these instructions!
INTENDED USE
The intended use of this power supply is to supply a stabilised output voltage 
corresponding to the technical indications. 
This device is an extremely versatile fi xed voltage power supply unit whose IC 
voltage regulator is equipped with an internal electronic and thermal overload 
protection device. It is suitable for almost all applications, e.g. for the operation 
of sets, assemblies and devices which require a well stabilised current supply. 
Owing to the overload protection mentioned before, this power supply module 
is also ideal for lab applications. 
The  device  has  an  LED  display. 
Any other use of the device is not 
permitted.
This  product  has  been  tested  in 
accordance with the EU guideline 
89/336/EU  (EMC  law  dated 
09.11.1992, 
Electromagnetic 
Com   pa  tibility) and complies with 
the legal stipulations.
2. Output voltage 
The  stabilised  output  voltage  is  taken  from  the  connection  terminals  marked 
„+“ and „–“. Observe the correct polarity of the voltage when connecting to a 
consumer. Incorrect poling can result in the destruction of the connected consumer. 
Make sure that the max. output current permissible for the power supply unit used 
is not exceeded in order to protect the device from over loading!
INSTALLATION IN A HOUSING
If the device is installed in a housing, suffi cient ventilation must be ensured. The 
cooler of the device can become very hot under certain circumstances. For this 
reason a metal housing with adequate cooling slits should be used. Make sure to 
observe the relevant VDE regulations when installing the device in a housing.
GUARANTEE
We grant a 2 years warranty for this product. The warranty includes the repair 
of  defects  which  result  clearly  from  incorrect  materials  or  manufacturing  mi-
stakes. For damages caused by not following the instructions the warranty will 
be stated void. For consequential damages resulting thereof, no liability can 
be taken. In the event of defects which occur as of delivery within the legal gu-
arantee period of two years, you have the legal right of subsequent fulfi llment 
(either: rectifi cation of the defect or delivery of a new product) and – if the legal 
prerequisites are met – the legal rights of reduction or withdrawal and additio-
nally compensation for damages. For reasons of safety and licensing (CE) it is 
not allowed to modify the unit. Any additional claims are excluded.
ENVIRONMENTAL PROTECTION
Please  note  that  electrical  and  electronic  devices  must  never  be 
disposed of in regular household waste. Consumers are legally re-
sponsible for the proper disposal of electronic and electrical devices 
by returning them to collecting sites designated for the recycling of 
electrical and electronic equipment waste.
STABILISED POWER 
SUPPLY UNITS 12/5 V
Art.-No. 19 08 35/19 07 95
SAFETY INSTRUCTIONS
When handling products which come into contact with electrical charge, the 
relevant VDE regulations must be observed. 
–  Assemblies and components must be kept out of reach of children.
–  In devices with an operation voltage >  35  Volts, fi nal installation may only be 
carried out by a qualifi ed electrician in accordance with the VDE regu lations.
–  Devices designed for mains operation may only be operated at 230  V/50  Hz. 
–  The correct fuses must be integrated in the connection lines for the device.
–  The device must be completely cut from the power supply before changing 
the fuse. 
–  If the device is installed in a housing, suffi cient air circulation must be ensured.
–  The device is designed for use in dry, clean rooms.
–  In industrial premises the relevant accident prevention regulations for electrical 
systems and equipment must be observed.
–  In schools, training centres, hobby and selfhelp workshops the operation of 
assemblies must be responsibly monitored by trained personnel.
–  Do not operate the assembly in an environment where there are fl ammable 
gases, vapours or dust or where these may occur.
MALFUNCTIONS 
If it can be assumed that a safe operation is no longer possible, the device 
has to be taken out of operation and be 
secured against accidental use if:
–  
the device shows mechanical damage.
–  
the device is not functioning.
–  
parts of the device are loose or not attached.
–  connecting cables show 
any visible damage
If the device needs to be repaired, only original spare parts may be used. 
The use of any other spare parts may lead to serious damage to property and 
personal injury! The device may only be repaired by a qualifi ed person.
CONNECTION INSTRUCTIONS
1. Mains connection
The mains voltage is connected at the terminals marked „230V/50Hz“. Make 
sure  to  observe  the  VDE  regulations,  as  incorrect  handling  of  230V  mains 
voltage can be fatal.
Technical Data
–  Input voltage: 230V/50Hz/~
–  Output voltage/current: 
19 08 35:   12 V/85 mA
19 07 95:   5 V/100 mA
– Short circuit resistant: brief
– Residual ripple: < 50 mV
– Operation temperature: 0°C – 40°C
This  manual  is  a  publication  of  H-TRONIC  GmbH,  Industriegebiet  Dienhof 11,  92242 
Hirschau,  Germany.  All  rights  including  translation  reserved.  Reprinting,  also  for  parts 
only, is prohibited. This manual is according to the technical status at the time of printing. 
Changes in technique, equipment and design reserved. We assume no liability for printing 
errors. © Copyright 2012 by H-TRONIC GmbH
Dieses kompakte Stromversorgungs-
modul liefert eine stabilisierte und 
kurzschlussfeste Ausgangsspannung. 
Es eignet sich für fast alle Anwen-
dungsbereiche, z.B. zum Betrieb 
von Bausätzen, Baugruppen und 
Geräten, die eine gute stabilisiere 
Stromversorgung erfordern. Durch den 
integrierten Überlastschutz ist dieses 
Stromversorgungsmodul auch für die 
Laborpraxis gut geeignet. Die Betriebs-
anzeige des Gerätes erfolgt durch 
eine Leuchtdiode. 
NETZTEIL-BAUSTEIN 5 V
www.h-tronic.de
Art.-Nr. 19 07 95
Technische Daten 
–  Versorgungsspannung: 
230V/50Hz/~
–  Ausgangspannung: 5 V =
– Ausgangsstrom: max. 100 mA
– Kurzschlussfest: kurzzeitig
– Restwelligkeit: < 50 mV
– Betriebstemperatur: 0°C – 40°C
 Diese Bedienungsanleitung ist eine Publikation der H-Tronic GmbH, 
Industriegebiet Dienhof 11, 92242 Hirschau. Alle Rechte einschließlich 
Übersetzung vorbehalten. Reproduktionen jeder Art, z.B. Fotokopie, 
Mikroverfi lmung oder die Erfassung in EDV-Anlagen, bedürfen der 
schriftlichen Genehmigung des Herausgebers. Nachdruck, auch 
auszugsweise, verboten. Diese Bedienungsanleitung entspricht dem 
technischen Stand bei Drucklegung und ist Bestandteil dieses Gerätes. 
Irrtümer und Änderung in Technik, Ausstattung und Design vorbehalten. 
© Copyright 2012 by H-TRONIC GmbH
H-TRONIC GmbH  Industriegebiet Dienhof 11  92242 Hirschau 
Tel. +49 (0)9622/7020-0  kontakt@h-tronic.de