Trinamic 11-0011 TMCM-171 BLDC Output For 3-phase BLDC Motors 11-0011 Data Sheet

Product codes
11-0011
Page of 134
 
TMCL Reference Manual 
14 
 
 
 
Trinamic Motion Control GmbH & Co KG 
Sternstraße 67 
D – 20357 Hamburg, Germany 
http://www.trinamic.com 
 
3.3  MST – Motor Stop 
Description: This instruction stops the motor.  
 
Internal function: the axis parameter "target velocity" is set to zero.  
 
Related commands: ROL, ROR, SAP, GAP  
 
Mnemonic: MST <motor number> 
 
Binary representation: 
INSTRUCTION NO. 
TYPE 
MOT/BANK 
VALUE 
(don't care) 
<motor number> 
            (don't care) 
 
Reply in direct mode: 
STATUS 
VALUE 
100 – OK 
(don't care) 
 
Parameter ranges: 
Module 
Motor number 
TMCM-300/301/302/303/310 
0..2 
TMCM-100 
always 0 
 
Example: Stop motor #1 
 
Mnemonic: MST 1 
 
Binary: 
Byte Index 
Function 
Target- 
address 
Instruction 
Number 
Type 
Motor/ 
Bank 
Operand 
Byte3 
Operand 
Byte2 
Operand 
Byte1 
Operand 
Byte0 
Checksum 
Value (hex) 
$01 
$03 
$00 
$01 
$00 
$00 
$00 
$00 
$05 
 
 
Note: 
With some modules it is possible to use stall detection. Please see section 6.4 for details.