Greisinger GMH3691 and GGO369 Oxygen Meter with Sensor 601667 Data Sheet

Product codes
601667
Page of 2
31
Handheld instrument
Display / Controller
Logger / EASYBus
Transmitter
Temperature probe
Alarm / Protection
Residual oxygen meas. device
for quick and cost-effective measure-
ment of residual oxygen
GMH
 
3691
 
GOG 
Application:
Essentially there, where delicate products are 
conserved by low-oxygen atmospheres (protec-
tive gas), this instrument is suitable to check the 
residual oxygen content.
  packaging industry
  food industry
Specifi cation:
(summary)
Meas. range: 0,0 ... 100,0 % O
2
(O
2
-concentration)
Accuracy: (whole system - during carefully 
calibration and measuring)
 1-point-calibration:  ±0.2 %O
2
 ±1 digit
 
         (for 
concentrations 
10%)
 2-point-calibration:  ±0.1 %O
2
  ±1 digit
 
         (for 
concentrations 
10%)
Oxygen probe:  Oxygen-partial pressure probe, 
built in external sensor housing
Response time: t
90
 < 10 sec., depending on 
temperature
Operation life: 
warranty for sensor element 
12 months 
(appropriate appli-
cation and ambient pressure)
Working pressure: 0.5 to 2.0 bar abs.
Over-/under-pressure: max. 0,25 bar
Working temperature:  0 to 50°C (sensor), 
 
          -20 to 50°C (device)
Relative humidity:  0 to +95%RH 
(non-condensing)
Storage temperature:  -15 to 60°C (sensor), 
 
          -20 to 70°C (device)
Power supply:  9V battery type IEC 6F22
Dimensions case: approx. 394 x 294 x 106 mm
Weight:  approx. 1400g  (cpl. set)
for additional technical data refer to 
GMH3691 and GGO369
Scope of supply:
Instrument GMH3691, hand pump with air tube, 
GOG oxygen sensor with penetration needle, case 
GKK3500, spare needle ø0,9mm, rubber foam 
Spare elements, accessories:
GOG-SET
Set without instrument
Scope of supply: GOG oxygen sensor with 
penetration needle, hand pump with air tube, case 
GKK3500, spare needle and 40 rubber foam sticker
GOEL 369
spare sensor element 
GOG-N
needle,
Ø
0.9 mm (5 pieces)
GOG-A
rubber foam sticker (40 pieces)
ST-R1
device protection bag
 with cut-out for probe connection
 for add. accessories  p.r.t. page 40/41
Atmospheric oxygen sensores
for devices of the GMH369x series
Spare elements, accessories:
GOEL 369 
spare sensor element for replacement by user
GOEL 370 
spare sensor element for replacement by user
GOEL 369 S 
spare sensor element for replacement by user 
ESA 369
  spare tube-adapter M16x1, for tubes with a inner-diameter of 15mm
GOO 369  
for universal application
GOO 370 
sensor for diving application
GOO 369 S 
O
2
sensor for high CO
2
 concentration
closed sensor type
open sensor type
 suitable for under and over pressure
 for using in gas-tight systems
Application:
Suitable for measuring in normal atmosphere 
and in systems without or with slight under or 
over pressure. The sensor type features a screw 
thread and can be built in gas-tight in almost every 
system directly resp. with tube-adapter 
 suitable for air- or gas-stream
 quick temperature compensation
Application:
Because of the special sensor construction the 
measuring gas streams optimally around the sen-
sor and escapes through holes in the housing into 
the air. No pressure build-up at slight streaming of 
the probe, that falsify the result of measurement.
Particularly suitable for measuring of gas out of 
gas-bottle etc. Even measuring indoor-gas con-
centration is possible.
GGO 369  
for universal application
GGO 370 
sensor for diving application
GGO 369 S 
O
2
sensor for high CO
2
concentration
Options: 
(for all types)
cable length 4m 
upcharges
cable length 10m 
upcharges
Specifi cation:
GGO/GOO 369 
GGO/GOO 370 
GGO/GOO 369 S
Application:    
 
standard  
diving
CO
2
 containing gases
Specifi c features:    
 
Stronger membrane 
Acidic electrolyte 
           
 
 
 
Coated electronics
           
 
 
 
independence on operating position 
           
 
 
 
temperature compensation
Measuring range:
Partial oxygen pressure:  0 ... 1100 hPa O
2
0 ... 1100 hPa O
2
0 ... 300 hPa O
2
Oxygen concentration: 
0,0 ... 100,0 % O
2
   
0,0 ... 100,0 % O
2
0,0 ... 25,0 % O
2
Temperature:  
0,0 ... 50,0 °C  
0,0 ... 45,0 °C 
0,0 ... 50,0 °C 
Response time: t
90
 
<5 sec. 
<10 sec. 
<15 sec.
Operating conditions:  
0 - 50 °C 
0 - 45 °C 
0 - 50 °C
 
 
 
 
 
 
 
 
   
0 - 95 %RH
0 - 95 %RH
0 - 95 %RH 
Ambient pressure:  
0,5 to 2,0 bar abs. 
0,5 to 2,0 bar abs. 
0,5 to 2,0 bar abs.
Over-/under-pressure:  max. 
0,25 bar
 (pressure difference sensor membrane to ambient – sensor screwed-in)
Storage temperature:  
-15 to +60 °C
Operation life:    
approx. two years (warranty for sensor element: 12 months)
Sensor:    
GOEL 369 
GOEL 370 
GOEL 369 S
           
 
 
Oxygen-partial pressure probe, mounted in external sensor housing
Connection:    
 
approx. 1,3 m cable with Mini-DIN-plug.
Dimensions of housing:  
approx. Ø 36 mm Housing with M16 x 1-screw thread
           
 
 
(sensor can be connected to line tubes by means of an additional adapter)
 
 
 
 
 
 
 
 
   
length: approx. 91 mm (141 mm incl. anti-buckling glanding)
Weight:    
 
 
approx. 135 g 
Scope of supply:
sensor, tube-adapter, fl ow diverter
N E W
N E W