Belden Bus cable for RS-485 applications (CAN bus) Grey 9842 Data Sheet
Product codes
9842
9842 Paired - Low Capacitance EIA RS-485
For more information please
call
1-800-Belden1
Color Code Chart : No. 5 for
Paired Cables (Western
Electric Standard).pdf
Description:
24 AWG stranded (7x32) tinned copper conductors, twisted pairs, polyethylene insulated, overall 100% Beldfoil® shield plus a 90% tinned
copper braid shield, 24 AWG (7x32) tinned copper drain wire, PVC jacket.
copper braid shield, 24 AWG (7x32) tinned copper drain wire, PVC jacket.
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Pairs
2
Total Number of Conductors
4
AWG
24
Stranding
7x32
Conductor Material
TC - Tinned Copper
INSULATION:
Insulation Material
PE - Polyethylene
Lay Length :
Lay Length (in.)
Direction
Twists/ft (twist/ft)
1.0
Left Hand Lay
12
Twists/ft.
12
Pair Color Code Chart :
Number
Color
1
White/Blue & Blue/White
Number
Color
2
White/Orange & Orange/White
OUTER SHIELD:
Outer Shield Material Trade Name
Beldfoil®
Outer Shield Type
Tape/Braid
Outer Shield Material :
Layer Number
Material Trade Name
Type
Material
% Coverage (%)
1
Beldfoil®
Tape
Aluminum Foil-Polyester
Tape
Tape
100
2
Braid
TC - Tinned Copper
90