Belden Orange 3077F003500 Data Sheet

Product codes
3077F003500
Page of 3
  
For more Information 
please call
1-800-Belden1
Description:
22 AWG stranded (7x30) tinned copper conductors, polyolefin insulation, Beldfoil® shield (100%
coverage), tinned copper drain wire, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (in.)
1
22
7x30
TC - Tinned Copper .030
Insulation
Insulation Material:
Insulation Material
PO - Polyolefin
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Coverage (%)
Beldfoil®
Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
20
7x28
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cabling
Overall Nominal Diameter:
0.196 in.
Pair
Pair Color Code Chart:
Number Color
1
Blue & Orange
Pair Lay Length & Direction:
Lay Length (in.)
1.500
Mechanical Characteristics (Overall)
Operating Temperature Range:
-30°C To +105°C
UL Temperature Rating:
105°C
Bulk Cable Weight:
18 lbs/1000 ft.
Max. Recommended Pulling Tension:
27 lbs.
Min. Bend Radius (Install)/Minor Axis:
2.200 in.
 
Page 1 of 3 
03-17-2011
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
3077F  Multi-Conductor - DataBus® ISA/SP-50 FOUNDATION Fieldbus Cable