Lappkabel 2170203 UNITRONIC® BUS LD Bus Cable 1 x 2 x 0.22 mm² Violet 2170203 Data Sheet

Product codes
2170203
Page of 1
DATA SHEET 
2170203 
 
UNITRONIC
®
 BUS LD  … x 2 x 0,22 mm² 
gültig ab : 
27.10.2009
 
 
elaborated by:
 
Petra Samek,  PDC       
Dokument: 
DB2170203EN04 
page 1 of 1 
 
Nr.: 0019/0408 
Application 
UNITRONIC
®
 BUS LD is a screened, twisted paired cable for bus systems with a data transmission rate up to 10 
MBit/s. The twisting of the conductors into pairs ensures maximum interference suppression of the individual 
signals. The copper screening protects against external electromagnetic influences.  
Cables of this composition are intended for limited flexible use and for permanent installation in dry and damp 
interiors. 
 
Applicable connectors: D-Sub-Connector, 9-pins; Round-Connector, 9-pins (system of protection IP 65) 
Design 
Conductor 
multiple wire stranding of bare copper wires 
Insulation 
special PE-based compound 
Core identification 
acc. to DIN 47100 
Stranding 
Cores twisted into pair, pairs twisted together 
Wrapping 
plastic foil 
Screening 
braiding of tinned copper wires 
Sheath 
special PVC-based compound 
Sheath colour 
violet similar to RAL 4001 
CableØ 1 pair 
approx. 5,7 mm (part no. 2170203) 
CableØ 2 pairs 
approx. 7,1 mm (part no. 2170204) 
CableØ 3 pairs 
approx. 7,2 mm (part no. 2170205) 
Electrical properties at 20°C 
Conductor resistance (loop) 
max. Ω/km 
186 
Insulation resistance 
min. GΩ x km 
Mutual capacitance at 800 Hz 
max. nF/km 
60 
Characteristic impedance 
Ω 
100 - 120 
Attenuation at 100 kHz 
nom. dB/100m 
0,9 
Attenuation at 1 MHz 
nom. dB/100m 
2,5 
Near-end cross talk attenuation at 1 MHz 
min. dB 
50 
Near-end cross talk attenuation at 10 MHz 
min. dB 
40 
Transfer impedance at 30 MHz 
max. mΩ/m 
250 
Nominal velocity of propagation 
nom. 
0,66 c 
Signal transit time 
nom. ns/m 
5,06 
Operating voltage (not for power purposes) 
 peak value V 
250 
Test voltage (conductor/conductor) 
1500 
Test voltage (conductor/screen) 
1000 
Mechanical and thermal properties 
Permissible temperature range (fixed use) 
°C 
-40 to +80 
Permissible temperature range (flexible use) 
°C 
-5 to +70 
Minimum bending radius (fixed use) 
cableØ x 
Minimum bending radius (flexible use) 
cableØ x 
20 
Flame propagation  
flame retardant to IEC 60 332-1-2 
Conformity 
This cable confirms to RoHS directive (2002/95/EG)