6.2 Status 
indicators 
 
 
 
 
 
 
 
 
 
 
7 Cleaning 
Note:
  
Disconnect the power plug before staring cleaning work.  
1.  Clean the bank note validator regularly using a lint-free, dry, soft cloth or soft brush.  
2.  If necessary, clean the sensors with a soft cloth moistened with a little soapy water.  
Transport and Storage 
Pack the bank note validator carefully before transporting or storing it.  
Note:
 
Observe the information regarding temperature and relative humidity (refer to Chapter 
X
9
X
). 
Note:
 
Do not let the bank note validator fall or expose it to any impacts. 
9 Technical 
Data 
 
Dimensions (W x H x L): 
138 x 80 x 162 mm 
Weight: 0.8 
kg 
Speed: 
2 bank notes / second 
Power consumption: 
Max. 6.5 W 
Power supply: 
AC 110V~240V, 50Hz/60Hz 
Rechargeable battery (NC 340): 
1 lithium-ion battery 11.1 V / 700 m Ah 
50 x 30 x 15 mm (not changeable) 
Operating time with fully charged battery and no power 
adapter plug (NC 340): 
Max. 90 minutes 
Temperature, operation: 
0 °C ~ 40 °C 
Temperature, storage: 
-15 °C ~ 50 °C 
Temperature, transport (max. 7 days): 
-25 °C ~ 55 °C 
Rel. humidity, operation: 
30% ~ 90% 
Rel. humidity, storage: 
Max. 80% (at 25°C) 
Rel. humidity, transport (max. 7 days): 
Max. 98% (at 25°C) 
Display icon 
Significance 
 
Discharge of the bank note occurs at the front infeed/discharge slot 
 
The bank note validator is connected to a PC. 
 
Battery charge status (full, empty) (only NC 340)