Intel E3815 FH8065301567411 Data Sheet
Product codes
FH8065301567411
Intel
®
Atom™ Processor E3800 Product Family
1122
Datasheet
Default: 00000000h
Type:
Memory Mapped I/O Register
(Size: 32 bits)
gpd_gp_reg_reg_gp_sp_stream_stat_b:
ISPMMADR Type:
PCI Configuration Register (Size: 32 bits)
ISPMMADR Reference:
[B:0, D:3, F:0] + 10h
31
28
24
20
16
12
8
4
0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
unu
sed
_
re
g_gp
_sp
_
st
re
am_s
tat_b
SP_STR_MON_GDC22
SP_
ac
cept
SP
_STR_MON_G
D
C
22SP
_
va
lid
SP_STR_MON_SP2GDC2_
ac
cept
SP
_STR_MON_SP2GDC
2_v
alid
SP_STR_MON_GDC12
SP_
ac
cept
SP
_STR_MON_G
D
C
12SP
_
va
lid
SP_STR_MON_SP2GDC1_
ac
cept
SP
_STR_MON_SP2GDC
1_v
alid
Bit
Range
Default &
Access
Description
31:8
0h
RW
unused_reg_gp_sp_stream_stat_b:
Unused
7
0h
RO
SP_STR_MON_GDC22SP_accept:
Returns the value 1 if the SP can accept an
acknowledge token from the FIFO between the GDC2 acknowledge port and the SP.
Returns the value 0 if the SP cannot accept a token on this SP input port.
6
0h
RO
SP_STR_MON_GDC22SP_valid:
Returns the value 1 if a valid acknowledge token
from the FIFO between the GDC2 acknowledge port and the SP, is present on the GDC2
input port of the SP. Returns the value 0 if there is no valid acknowledge token available
on this SP input port.
5
0h
RO
SP_STR_MON_SP2GDC2_accept:
Returns the value 1 if the command FIFO between
SP and GDC2 can accept a command from the SP. Returns the value 0 if this command
FIFO cannot accept a command from the SP.
4
0h
RO
SP_STR_MON_SP2GDC2_valid:
Returns the value 1 if SP sends a command using
the streaming port connected to GDC2 command FIFO. Returns the value 0 if the SP
does not send a command to GDC2
3
0h
RO
SP_STR_MON_GDC12SP_accept:
Returns the value 1 if the SP can accept an
acknowledge token from the FIFO between the GDC1 acknowledge port and the SP.
Returns the value 0 if the SP cannot accept a token on this SP input port.
2
0h
RO
SP_STR_MON_GDC12SP_valid:
Returns the value 1 if a valid acknowledge token
from the FIFO between the GDC1 acknowledge port and the SP, is present on the GDC1
input port of the SP. Returns the value 0 if there is no valid acknowledge token available
on this SP input port.
1
0h
RO
SP_STR_MON_SP2GDC1_accept:
Returns the value 1 if the command FIFO between
SP and GDC1 can accept a command from the SP. Returns the value 0 if this command
FIFO cannot accept a command from the SP.
0
0h
RO
SP_STR_MON_SP2GDC1_valid:
Returns the value 1 if SP sends a command using
the streaming port connected to GDC1 command FIFO. Returns the value 0 if the SP
does not send a command to GDC1