Intel E3815 FH8065301567411 Data Sheet

Product codes
FH8065301567411
Page of 5308
Intel
®
 Atom™ Processor E3800 Product Family
2146
Datasheet
Default: 00002000h
18.6.36
Super Speed Configuration 1 (SSCFG1)—Offset B0h
Refer to the switching flows section of this document. Not for EDS
31
28
24
20
16
12
8
4
0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0
Rsvd
1
HSA
A
IM
HS
OAA
PEP
M
HS
IA
APE
PM
HSIIP
APC
H
S
IIP
ANEPT
HS
II
PA
SI
T
Bit 
Range
Default & 
Access
Field Name (ID): Description
31:16
0000h
RO
Rsvd1: 
Reserved.
Power Well: 
Core
15
0h
RW
HS ASYNC Active IN Mask (HSAAIM): 
Determines if the Async Active will mask/
ignore IN EP s. 0 HS ASYNC Active will include IN EP s. 1 HS ASYNC Active will mask/
ignore IN EP s.
Power Well: 
Core
14
0h
RW
HS OUT ASYNC Active Polling EP Mask (HSOAAPEPM): 
Determines if the Async 
Active for OUT HS/FS/LS masks/ignores EP s that are polling/PINGing (HS) due to NAK. 
0 HS OUT ASYNC Active will include EP s that are polling. 1 HS OUT ASYNC Active will 
mask/ignore EP s that are polling.
Power Well: 
Core
13
1h
RW
HS IN ASYNC Active Polling EP Mask (HSIAAPEPM): 
Determines if the Async Active 
for IN HS/FS/LS masks/ignores EP s that are polling due to NAK. 0 HS IN ASYNC Active 
will include EP s that are polling. 1 HS IN ASYNC Active will mask/ignore EP s that are 
polling.
Power Well: 
Core
12:11
0h
RW
HS INTR IN Periodic Active Policy Control (HSIIPAPC): 
Controls how the HS INTR 
IN periodic active is used to generate the global periodic active. This will determine how 
the smallest service interval among active EP s and number of active EP s are used. 0 
HS INTR IN periodic active will be used to generate periodic active if Service Interval 
Threshold OR Numb of EP Threshold values meet the requirement. 1 HS INTR IN 
periodic active will be used to generate periodic active if Service Interval Threshold AND 
Numb of EP Threshold values meet the requirement. 2 Always allow HS INTR EP s to be 
used in the generation of the global Periodic Active indication. 3 Never allow HS INTR EP 
s to be used in the generation of the global Periodic Active indicaiton
Power Well: 
Core
10:4
00h
RW
HS INTR IN Periodic Active Num of EP Threshold (HSIIPANEPT): 
Defines the 
threshold used to determine if Periodic Acive may include HS/FS/LS INTR IN EP active 
indication. If there are more than NumEPThreshold active HS/FS/LS INTR EP s then they 
may be included as part of the periodic active generation.
Power Well: 
Core
3:0
0h
RW
HS INTR IN Periodic Active Service Interval Threshold (HSIIPASIT): 
Defines the 
Service Interval threshold used to determine if Periodic Acive will include HS/FS/LS INTR 
IN EP active indication. If there are any active HS/FS/LS INTR EP s with a service 
interval less than or equal to this threshold then they may be included as part of the 
periodic active generation.
Power Well: 