Intel E3815 FH8065301567411 Data Sheet

Product codes
FH8065301567411
Page of 5308
 
Intel
®
 Atom™ Processor E3800 Product Family
Datasheet
2401
4
0b
RO
Over-current Active (OCACT_P0_0): 1=This port currently has an over-
current condition. 0=This port does not have an over-current condition. This 
bit will automatically transition from a one to a zero when the over current 
condition is removed. The functionality of this bit is not dependent upon the 
port owner. The Intel EHC automatically disables the port when the over-
current active bit is '1'.
Power Well: Resume
3
0b
RWC
Port Enable/Disable Change (PEDC_P0_0): 1=Port enabled/disabled 
status has changed. 0=No change. For the root hub, this bit gets set to a one 
only when a port is disabled due to the appropriate conditions existing at the 
EOF2 point (See Chapter 11 of the USB Specification for the definition of a 
port error). This bit is not set due to the Disabled-to-Enabled transition, nor 
due to a disconnect. Software clears this bit by writing a 1 to it.
Power Well: Resume
2
0b
RO
Reserved (RSVD): Reserved.
1
0b
RWC
Connect Status Change (CSC_P0_0): 1=Change in Current Connect 
Status. 0=No change. Indicates a change has occurred in the port's Current 
Connect Status. The host controller sets this bit for all changes to the port 
device connect status, even if system software has not cleared an existing 
connect status change. For example, the insertion status changes twice 
before system software has cleared the changed condition, hub hardware will 
be 'setting' an already-set bit (i.e., the bit will remain set). Software sets this 
bit to 0 by writing a 1 to it.
Power Well: Resume
0
0b
RO
Current Connect Status (CCS_P0_0): 1=Device is present on port. 0=No 
device is present. This value reflects the current state of the port, and may 
not correspond directly to the event that caused the Connect Status Change 
bit (Bit 1) to be set.
Power Well: Resume
Bit 
Range
Default 
& Access
Field Name (ID): Description