Bunn Ice Tea Maker AFPO-3 User Manual

Page of 25
21
VACUUM SWITCHES
FIG. 26 VACUUM SWITCHES
Location:
  The vacuum switches are located inside autofill 
box, mounted on the left side of the solenoid mounting 
bracket just below the needle valves.
 
Test Procedure:
1.  Disconnect the dispenser from the power 
source. 
2.  Disconnect flavor input lines.
3.  Disconnect white/red, red/black or the brown/black 
wires on the vacuum switch.
4.   Check for continuity across the switch leads.
SERVICE (cont.)
P1521
FL
AV
OR
INP
UT
1  
 
2
WA
TE
R
INP
UT
RE
FIL
L
MA
IN
PO
WE
R
2
1
1
2
3
3
3
FL
AV
OR
OU
TP
UT
FL
AV
OR
OU
TP
UT
WA
TE
R
OU
TP
UT
FL
AV
OR
OU
TP
UT
WA
TE
R
OU
TP
UT
WA
TE
R
OU
TP
UT
If continuity is not present as described, the vacuum 
switch is operating properly.
If continuity is present as described, without a vacuum 
generated by an empty product concentrate, replace 
the vacuum switch.
Removal and Replacement:
1.  Disconnect dispenser from the power source.
2.  Removal of the two #8-32 keps nuts securing 
the pump/motor assembly nearest the vacuum 
switches is required to access the lower vacuum 
switch.
3.  Disconnect the input tubes from the vacuum switch 
to be replaced.
4.  Disconnect the wires on the vacuum switch to be 
removed.
5.  Remove the two #4-40 screws securing the vacuum 
switch to the solenoid bracket. Remove and discard 
switch.
6.  Using two #4-40 screws secure the new vacuum 
switch to the solenoid bracket.
7.  Refer to Fig. 27 and reconnect the wires.
8.  Connect the input tubes to the new vacuum 
switch.
9.   Restore the pump/motor assembly to its normal 
mounting position using the two #8-32 keps 
nuts.           
#1
#2
#3
WHI/RED from Refill ON/OFF Switch #3
WHI/RED to Circuit Board J4-2
RED/BLK from Refill ON/OFF Switch #1
RED/BLK to Circuit Board J4-5
BRN/BLK from Refill ON/OFF Switch #2
BRN/BLK to Circuit Board J4-4
FIG. 27 VACUUM SWITCH TERMINALS
P1527
41093 040408