AltiGen comm TRITON T1 User Manual

Page of 4
TRITON T1 BOARD
Q
U I C K
I
N S TA L L AT I O N
G
U I D E
M
INIMUM
S
YSTEM
R
EQUIREMENTS
:
• IBM/PC AT compatible system with adequate number of full-size ISA and PCI slots
• 233 Mhz Pentium processor (or better)
• 2 - 4 GB Hard Disk Drive Space (depending on voicemail requirements)
• Windows NT Server 4.0 with Service Pack 4 (or higher) installed
• 128 MB RAM
• AltiGen’s Quantum Telephony Board (one or more, Rev. D or higher)
• AltiGen’s Triton T1 Board (one or more) 
• AltiWare OE R3.0 (or higher)
• 300W/10A CPU Power (minimum required to power AltiGen boards only)
• CSU (Channel Service Unit)
*** Faulty signals include the following: yellow alarm, bipolar violation or frame error
MVIP BUS
Termination Switch
MVIP  Connector
TRITON T1 BOARD
System
Configuration Switch
# of AltiGen Boards
# of Slots**
CPU
HDD
1 Triton T1, 1-3 Quantum
2 PCI, 3 ISA
233 Mhz
2GB
1 Triton T1, 1-6 Quantum
2 PCI, 6 ISA
300 Mhz
2GB
1-4 Triton T1, 1-10 Quantum                5 PCI, 10 ISA
350 Mhz
4GB
# of AltiGen Boards
Power Supply**
Typical Power Supply 
1 Triton T1, 1-3 Quantum
+12V: 4.2 Amps  +5V: 6Amps
300W/30A@5V/12A@12V
1 Triton T1, 1-6 Quantum
+12V: 8.4 Amps  +5V: 10.8Amps
400W/40A@5V/16A@12V
1-4 Triton T1, 1-10 Quantum              +12V: 14 Amps   +5V: 21Amps
400W/40A@5V/16A@12V
GREEN LED
RED LED
Status 
OFF
OFF
No power
ON
OFF
Normal operation
OFF
ON
No signal
ON
Flashing
Faulty signal with frame synchronization***
OFF
Flashing                           Faulty signal without frame synchronization
Alternating
Alternating
Frame slips in normal operation
The Triton T1 Board uses the following signaling and framing features:
Signaling: loop start, ground start, E&M immediate start, E&M wink start*
Line Encoding: AMI, B8ZS*
*recommended
** The above system requirements are for AltiGen components only, and do not take into account requirements for other
system components such as motherboard, disk drives, etc.
LED Indicators