Behringer Ultrazone ZMX8210 User Manual

Page of 12
ULTRAZONE ZMX8210
Controls and connectors
5
Introduction
1. 
Thank  you  for  purchasing  the  ULTRAZONE  ZMX8210.  The 
ZMX8210 is a professional rack mixer which is especially suitable 
for fixed installation applications and allows public address to be 
directed to up to three zones (rooms). The eight input channels 
process Line and Microphone signals. Further inputs are added 
by connecting a second ZMX8210. All channels have high-quality 
preamplifiers  to ensure the highest  level  of sound  quality. The 
input signals can flexibly be routed to three output buses as well 
as effectively be processed with the integrated 4-band equalizer. 
Several functions of the ZMX8210 can be controlled remotely by 
using simple control elements. Thanks to its intuitive control panel, 
the unit can also be employed by inexperienced users after a short 
while unlike conventional mixers.
The ZMX8210 gives you full control in no time to direct public 
address into every setting .
Have fun with your new mixer.
Before getting started
1.1 
Shipment
1.1.1 
Your  ZMX8210  was  carefully  packed  at  the  factory,  and  the 
packaging was designed to protect the unit from rough handling. 
Nevertheless,  we  recommend  that  you  carefully  examine  the 
packaging and its contents for any signs of physical damage that 
may have occurred during transit.
If the unit is damaged, please do NOT return it to BEH-
 
+
RINGER. Instead, notify your dealer and the shipping 
company  immediately.  Otherwise,  claims  for  damage 
or replacement may not be honored.
Always use the original packing carton to prevent dam-
 
+
age during storage or transport.
Make sure that no children are left unsupervised with 
 
+
the unit or its packaging.
Please  ensure  proper  disposal  of  all  packing  materi-
 
+
als.
Initial operation
1.1.2 
Be sure that there is enough space around the unit for cooling. 
To  avoid  overheating,  please  do  not  place  the  ZMX8210  near 
radiators and other equipment emanating heat.
Blown fuses must be replaced by fuses of the same type 
 
+
and rating! The correct value is specified in “Specifica-
tions.” Unplug the unit before replacing the fuse!
The mains connection is made using the enclosed power cord and 
a standard IEC receptacle. It meets all of the international safety 
certification requirements.
Please make sure that all units have a proper ground 
 
+
connection. For your own safety, never remove or dis-
able the ground conductor from the unit or of the AC 
power cord. The unit shall always be connected to the 
mains socket outlet with a protective ground connec-
tion.
Please  ensure  that  only  qualified  people  install  and 
 
+
operate  the  unit.  During  installation  and  operation, 
the user must have sufficient electrical contact to the 
ground, otherwise electrostatic discharges might affect 
the operation of the unit.
The sound quality may diminish within the range of pow-
 
+
erful broadcasting stations and high-frequency sources. 
Increase the distance between the transmitter and the 
device and use shielded cables for all connections.
Online registration
1.1.3 
Please remember to register your new BEHRINGER equipment right 
after your purchase by visiting www.behringer.com (alternatively  
www.behringer.de)  and  read  the  terms  and  conditions  of  our 
warranty carefully.
Should your BEHRINGER product malfunction, our goal is to have 
it repaired as quickly as possible. Please contact the retailer from 
whom the equipment was purchased. Should your BEHRINGER 
dealer not be located in your vicinity, you may directly contact 
one  of  our  subsidiaries.  Corresponding  contact  information  is 
included  in  the  original  equipment  packaging  (Global  Contact 
Information/European Contact Information). Should your country 
not be listed, please contact the distributor nearest you. A list of 
distributors can be found in the support area of our website (www.
behringer.com/support).
Registering your purchase and equipment with us helps us process 
your repair claims quicker and more efficiently.
Thank you for your cooperation!
Controls and connectors
2. 
Front panel
2.1 
The controls of channels 1 – 6 and 7 – 8 are largely identical as 
well as the controls of the LEFT, RIGHT and AUX buses. Channels 
1 and 7 plus the LEFT bus are described exemplarily.
Pressing the switch controls, unless otherwise noted, activates the 
described functions, but are deactivated when not pressed.
 
Controls of the ZMX8210
Fig. 2.1: 
Channels 1 – 6
PAD: The switch attenuates the input level of loud signal 
{1} 
sources by 20 dB.
+48 V: The switch activates the phantom power for capaci-
{2} 
tor microphones.
L, R, AUX: The three switches route the channel signals to 
{3} 
one or more output buses.
THRESH (only Channel 1): The knob selects the level at 
{4} 
which the signal is muted. When the level of the input signal 
exceeds the specified value, the signal of channels 2 – 8 on 
the LEFT/RIGHT bus is muted. Apply the Mute function to 
fade out music signals as soon as a microphone on channel 
1 is talked into.
LEVEL: This knob adjusts the preamplification and the level 
{5} 
with which the input signal is sent to the selected buses.
LEDs: The  LEDs  show  the  input  levels.  When  the  CLIP 
{6} 
LED  lights  up,  the  input  level  needs  to  be  attenuated  by 
using the LEVEL knob {5} to prevent clipping. In case the 
attenuation is insufficient, use PAD switch {1} to attenuate 
the signal further.
Channels 7 – 8
MONO: This switch selects the configuration of the stereo 
{7} 
channels:
In  mono  mode  (switch  pressed),  the  channel's  L/R 
 
=
inputs are mixed together and sent to the LEFT, RIGHT 
and AUX buses. In this way, a mono signal is sent to all 
output buses at the same time.