SERVICE (cont.)
LIMIT THERMOSTAT
FIG. 20 LIMIT THERMOSTAT
P1445
Location:
The limit thermostat is located in the center of
the tank lid.
Test Procedures:
1.
Disconnect the dispenser from the power source.
2.
Disconnect both black wires from the limit ther-
mostat.
3.
Check for continuity across the limit thermostat
terminals.
If continuity is present as described, the limit thermo-
stat is operating properly.
If continuity is not present as described, replace the
limit thermostat.
FIG. 21 LIMIT THERMOSTAT TERMINALS
P1800
Removal and Replacement:
1.
Remove all wires from the limit thermostat ter-
minals.
2.
Carefully slide the limit thermostat out from un-
der the retaining clip and remove the limit ther-
mostat.
3.
Carefully slide the new limit thermostat into the
retaining clip.
4.
Refer to Fig. 21 when reconnecting the wires.
BLK to Tank Heater
BLK to Control
Thermostat