MAINTENANCE
Battery Replacement
1.  Remove the spark plug wire from spark plug.
2.  Loosen and remove the nuts on the battery hold-
down plate and remove the plate from the support 
rods (see Figure 58).
1
2
3
Figure 58
1 -  Nuts
2 -   Battery Hold- 
Down Plate
3 -  Support Rods 
3.  Tip the battery forward slightly to access battery 
cables.
4.  Disconnect the black negative (-) battery cable from 
the battery first.
5.  Disconnect the red positive (+) battery cable 
second and remove the battery.
1
2
Figure 59
1 -   Red Positive (+) 
Battery Cable
2 -   Black Negative (-) 
Battery Cable
NOTICE
Dispose of the used battery properly according to 
the guidelines established by your local or state 
government.
6.  Install the new battery into the generator frame.
7.  Connect the red positive (+) battery cable to the 
battery first.
8.  Connect the black negative (-) battery cable to the 
battery second.
9.  Install the battery hold-down plate using the nuts 
removed in step 2.
10.  Install the spark plug wire onto spark plug.
The battery for 10KPRO, Part No. 100170, is the same 
as a wheelchair battery.
Type
Sealed lead-acid
Model
LA-12V20-NB
Volts
12
Amp
21
Dimensions (L x H x W)
7.13 x 3 x 6.63 in. 
(18.1 x 7.6 x 16.8 cm)