1 -    Battery Charger Port: Plug the 120-volt 
AC charger into this port to charge the 
generator battery.
2 -    Low Idle Control: With the smart idle switch 
in the ON (I) position, if there is no load 
present to any of the outlets for 5 seconds 
or longer, the engine speed will reduce to 
1800 RPM. If a load is applied to any of the 
outlets, the engine speed will automatically 
increase to 3600 RPM. With the smart idle 
control in the OFF (O) position, the engine 
will constantly run at 3600 RPM.
3 -    20-Amp Circuit Breakers: Each circuit 
breaker limits the current that can be 
delivered through the 120-volt duplex outlets 
to 20 amps.
4 -     Data Center: The data center displays 
voltage, frequency and accumulated run 
time.
5 -    120/240-Volt, 30-Amp Twist Lock Outlet 
(NEMA L14-30): The outlet can supply 
either 120V or 240V output up to 30 amps.
6 -    Ground Fault Sensor: The sensor will 
scan all the outlets on the control panel for 
a ground fault. If a ground fault is detected 
from any of the outlets, the sensor will 
automatically trip the main circuit breaker. 
7 -    Ground Terminal: The ground terminal is 
used to ground the generator.
8 -    Main Circuit Breaker: The main circuit 
breaker controls total output of all outlets to 
protect the generator.
9 -    120-Volt, 30-Amp Twist Lock Outlet: The 
outlet can supply 120V output up to 30 amps.
10 -   120-Volt, 20-Amp Duplex Outlets: Each 
outlet is capable of carrying a maximum of 
20 amps on a single outlet or a combination 
of all outlets.
11 -   Remote Start Program Button: Use this 
button along with the key fob to program the 
generator to be started remotely.
12 -   Remote Start Indicator Light: The light will 
light or flash depending on the status of the 
remote start system.