Bunn SILVER SERIES JDF-4S User Manual

Page of 28
6
INITIAL FILL
 CAUTION: The dispenser must be disconnected from the power source throughout the initial fill except when 
specified in the instructions.
1.  Remove drip tray assembly and splash panel from the dispenser. Replace the drip tray.
2.  Connect the water source to the back of the dispenser.
3.  Pull the fill tube from the dispenser, remove the plug and connect it to the dispense nozzle.
4.  Place the Dispense Lockout switch in the OFF position.
5.  Connect dispenser to the power source. Press and hold the dispense button for the dispense station that the 
tube is connected to for 10 seconds, until you hear the water valve turn on.
6.  Monitor the water bath fill level until water starts to trickle from the overflow tube. Then press the dispense 
button again to stop the fill process.
NOTE: The fill timer may time out before filling is complete. Press and hold the dispense button for 10 seconds 
to start again if needed.
FIG  1  Plumbing Connections - JDF-2S
PLUMBING HOOKUP
 
The plumbing connection is located on the rear of the dispenser. A 3/8" (9.52 mm) male flare adapter fitting 
is supplied, installed on the rear of the dispenser.
P3580-1
FIG  3  Initial Fill Hose - JDF-2S
P3581-1
39992 042007
FIG  2  Plumbing Connections - JDF-4S
FIG  4  Initial Fill Hose - JDF-4S
P3841
P3846