Rinse Alarm Feature
Periodic  rinsing  of  the  mix  chambers  and  dispense  tips  is  essential  for  proper  maintenance  and  optimum 
performance of the dispenser. The automated Rinse Alarm feature has three levels of operation; see Programming 
the Dispenser to select the desired alarm mode.
Alarm Level 
Alarm Mode
Disabled 
None
Warning Only 
“Rinse Required” will be displayed 4 hrs prior to the selected time interval to remind the 
operator that the Rinse Procedure needs to be preformed soon. The dispenser will continue 
to serve product, even if the full time interval elapses. 
Brew Lockout 
“Rinse Required” will be displayed 4 hrs prior to the selected time interval to remind the 
operator that the Rinse Procedure needs to be preformed soon. However, the dispenser will 
Lockout and not continue to serve product once the selected time interval has elapsed.
NOTE: The time interval between Rinses is adjustable from 8 to 24 hrs. The dispenser is shipped with the Rinse 
Alarm disabled, (No Alarm). It is up to the user to determine the Rinse time interval and the level of warning 
required, based on their application and maintenance procedures.
Rinse Procedure:
1.   Select Rinse on the Function Selector switch.
2.   Place a 2 Liter (1/2 Gal) container under the dispense tip.
3.   Activate any of the dispense switches until the water flow stops automatically, approximately 10 sec. The 
Rinse Alarm message will go away, when the Rinse procedure has been satisfied.
4.   Select Run on the Function Selector switch.