Bunn LCR-3 User Manual

Page of 27
13
ENTER  PASSWORD
(-)      0     (+)
SET  PASSWORD ?
(-)      0     (+)
2 OR 3  PRODUCTS?
  (2)     EXIT     (3)
SELECT  UNITS
ENG   EXIT   METRIC
REFRIGERATION  ?
  ON     EXIT     OFF
DEICE CYCLE TIME
(-)    120 MIN   (+)
RINSE ALARM  ?
NO    EXIT    YES
RINSE TIME  ?
(-)      12 HRS     (+)
RINSE LOCKOUT  ?
NO    EXIT    YES
The following functions can be Password Protected. If you wish to prevent others from accessing these functions, 
enter a 4 digit code of your choice. Record your password code [_ _ _ _], as you will need it to access these 
functions in the future.
Use the (+) or (-) buttons to 
enter password.
Use the (+) or (-) buttons to 
change the password.
Select the number of products 
to be dispensed
Select the preferred units.
Select  OFF  to  disable  the 
Refrigeration system
Select the time delay between 
automatic  deicing  of  the 
cabinet
Select (YES) or (NO)
Use the (+) or (-) buttons to 
adjust Rinse Alarm delay.
Select (YES) to enable
Enter  the  access  Code  to  view  the  remaining 
functions. Factory Default = 0.
Enter  your  own  Code  to  prevent  access  to  the 
remaining functions. [0 to 9999]
Used  to  switch  from  standard  3  products  to  2 
products w/Autoswitching of the Left and Middle 
Bibs.
Used to select the preferred units of measurement. 
(Oz., Gal, deg F) or (mL, L, deg C)
Select OFF to temporarily override a cooling system 
fault and allow the machine to dispense coffee.
If ice builds up on the evaporator - decrease the 
delay. If the cabinet is not cold enough - increase 
the delay.
Factory Default=120 (2 hrs)[min=30, max=180]
Selecting  Yes will enable the Rinse Alarm function, 
(see Rinse Alarm)
Enter  the  desired  time  between  required  Rinse 
Cycles in hours. [8 to 24 hrs]
Select YES to Lockout dispensing until the Rinse 
Alarm has been cleared. Default is NO.
 
LCD DISPLAY 
ACTION 
DESCRIPTION
PROGRAMMING (Continued)
41129 071409
TANK TEMP 190
(-)    EXIT    (+)
READY TEMP 180
(-)    EXIT    (+)
CABINET TEMP 38
(-)    EXIT    (+)
Use the (+) or (-) buttons to 
adjust the target Temp.
Use the (+) or (-) buttons to 
adjust the target Temp.
Use the (+) or (-) buttons to 
adjust the target Temp.
Sets the water Tank temperature:
(120 - 200°F) or (49 - 93°C)
Sets the hot water Ready temperature:
Typically set to the min. desired dispense temp.
Sets the Chilled cabinet target temperature:
(38 - 50°F) or (3 - 10°C)
 
LCD DISPLAY 
ACTION 
DESCRIPTION
If ON
If YES
If NO
to Next Page