Bunn LCR-3 User Manual

Page of 27
16
 
LCD DISPLAY 
 ACTION 
   DESCRIPTION
PROGRAMMING (Continued)
XXOVERFLOW > 155
(-)    EXIT   (+)
 XX REFILL -> 155
(-) EXIT (+)
WTR START DELAY
(-) .15SEC (+)
WTR STOP DELAY
(-) .15SEC (+)
TEST SWITCHES ?
UseSwitchToTest
TEST REFILL ?
EXIT YES
TEST HEATER ?
EXIT YES
ENTER ASSET #
(-)  000000  (+)
SERIAL #
LCR 0000000
VIEW FAULTS?
(-)     EXIT     (+)
LATEST FAULT
NO FAULTS
FACTORY DEFAULTS
 
NO 
YES
Use the (+) or (-) buttons to 
adjust Overflow threshold
Use the (+) or (-) buttons to 
adjust Refill threshold
Use the (+) or (-) buttons to 
adjust delay time
Use the (+) or (-) buttons to 
adjust delay time
NONE
Momentarily depress (YES)
Momentarily depress (YES)
Use the (+) or (-) buttons to 
enter the ASSET NUMBER
NONE
Select  (+)  to  view  the  Fault 
Conditions
Use  the  (+)  or  (-)  to  scroll 
through the Faults
Select (YES) or (NO)
Used to set the Conductance Threshold for the 
Tank Overflow Probe
Used to set the Conductance Threshold for the 
Tank Refill Probe.
Dispense Valve ON Delay. Eliminates weak mix 
at the beginning of a dispense.
Dispense  Valve  OFF  Delay.  Flushes  the  mix 
chamber at the end of a dispense.
Switch Diagnostic: Activate switches separately to 
test. Display will indicate which Switch has been 
activated. NOTE: Door Interlock switch must be 
held closed.
Refill Valve Diagnostic: Press YES to momentarily 
energize the Solenoid. CAUTION: Inlet Valve will 
open and water will flow, if connected and turned 
ON.
Tank Heater Diagnostic: Press YES to momentarily 
energize the Tank Heater Circuit. CAUTION: AC 
power will be applied to the Tank Heater Circuit.
Allows the user the option of entering an Asset 
Number. Default is 000000
Displays the manufacture’s Serial Number (should 
be  identical  to  the  Serial  Number  on  the  Data 
Plate)
This  unit  stores  the  last  3  Fault  Conditions  in 
memory for diagnostic purposes. 
Displays  up  to  3  FAULT  Conditions  or  NO 
FAULTS, if nothing has failed since the last “Reset 
Defaults”.
CAUTION: Selecting YES will RESET all Program-
ming Functions to the Factory Default settings
41129 021709