SERVICE (cont.)
Solenoid Valve (Late Models)
Location:
The solenoid valve is located inside the rear of the
dispenser on the right side near the bottom.
To test the solenoid valve, access will also be needed
to the electronic control board.
sound after approximately 5 seconds, as the coil
magnet attracts the plunger.
8. Disconnect the dispenser from the power source.
9. Reconnect the pink wire to terminal 5 of the elec-
tronic control board.
If the sound was heard as described and water will
not pass through the solenoid valve, there may be a
blockage in the water line before or after the solenoid
valve or the solenoid valve may require inspection for
wear and removal of waterborne particles.
If the sound was not heard as described, replace the
solenoid valve.
Removal and Replacement:
1. Remove all wires from the solenoid valve coil.
2. Turn-off the water supply to the dispenser.
3. Disconnect the water line from the solenoid valve.
4. Remove the two 8-32 slotted-head screws holding
the solenoid valve and mounting bracket to the back
panel.
5. Lift-out the solenoid valve.
6. Securely install the new solenoid valve to the back
panel.
7. Securely fasten the water line to the solenoid valve.
8. Reconnect the wires, FIG. 8.
Fill w
ater
tank
befo
re tu
rnin
g -o
n
ther
mos
tat o
r co
nne
ctin
g ap
plia
nce
to p
owe
r so
urce
.
Do n
ot u
se n
ear c
om
bus
tible
s.
Follo
w na
tion
al/lo
cal e
lectr
ical c
ode
s.
Elec
trica
lly g
roun
d th
e ch
assis
.
Use
only
on a
pro
perly
pro
tecte
d
circ
uit c
apa
ble o
f the
rate
d lo
ad.
FAILUR
E TO
CO
MPL
Y RISKS
EQUI
PME
NT
DAM
AGE,
FIR
E, O
R SH
OCK
HA
ZAR
D
READ
THE
EN
TIR
E OP
ERA
TIN
G MA
NUA
L
INC
LUD
ING
TH
E LIM
IT OF
WA
RR
ANTY
AN
D
LIABI
LIT
Y BE
FO
RE BU
YIN
G O
R U
SIN
G TH
IS PR
OD
UCT
THIS
APPL
IAN
CE
IS
HEA
TED
WHEN
EV
ER
CON
NE
CTE
D TO
A POWE
R SO
URC
E
0083
1.000
0A 5
/88 ©
1988
BUN
N-O-MA
TIC C
ORPO
RATIO
N
WARN
ING
!
Test Procedure:
1. Disconnect the dispenser from the power source
and turn-off the water supply to the dispenser.
2. Remove the pink wire from terminal 5 of the elec-
tronic control board.
3. Check the voltage across the solenoid valve coil
terminals with a voltmeter. Connect the dispenser
to the power source. The indication must be:
a.) 100 to 120 volts ac for 100 to 120 volt models
or
b.) 200 to 240 volts ac for 200 to 240 volt models
or
c.) 230 volts ac for 230 volt models
after a delay of approximately 5 seconds.
4. Disconnect the dispenser from the power source.
If voltage was present as described, proceed to #5.
If voltage was not present as described, refer to the Wir-
ing Diagrams and check the dispenser wiring harness.
5. Remove both wires from the solenoid valve coil
terminals.
6. Check for continuity across the solenoid valve coil
terminals.
If continuity is present as described, reconnect the wires
and proceed to #7.
If continuity is not present as described, replace the
solenoid valve coil.
7. Check the solenoid valve for coil action. Connect
the dispenser to the power source. Listen carefully
in the vicinity of the solenoid valve for a “clicking”
FIG. 14a SOLENOID VALVE
FIG. 14b SOLENOID VALVE WIRING
WHI/BLU to Electronic
Control Board T1
P1778
WHI or RED to
Terminal Block
42311 071310
H 5