Bunn Beverage Dispenser DV User Manual

Page of 25
5
TROUBLESHOOTING (cont.)
Problem 
Probable Cause 
Remedy 
Equipment will not operate 
(cont.)
Automatic refill will not oper-
ate after drawing hot water.
Water flows into the tank con-
tinuously (Dispenser discon-
nected from power source).
Water flows into the tank con-
tinuously (Dispenser connect-
ed to power source).
Water is cold.
2. Safety overflow switch
1. No water
2. Water strainer/flow control
3. Liquid level system
4. Solenoid valve
1. Solenoid valve
1. Liquid level system
1. Safety overflow switch
2. Limit thermostat
3. Tank heater
4. Temperature control
Refer to Service – safety overflow switch 
for testing procedures. 
Check plumbing and shut-off valves.
(A) Direction of flow arrow must be point-
ing towards dispenser.
(B) Remove the strainer/flow control and 
check for obstructions. Clear or replace.
Refer to Service – electronic controls for 
testing procedures.
Refer to Service – solenoid valve for test-
ing procedures.
Refer to Service – solenoid valve for test-
ing procedures.
Refer to Service – electronic controls for 
testing procedures.
Refer to Service – safety overflow switch 
for testing procedures. 
Refer to Service – limit thermostat for 
testing procedures.
Refer to Service – tank heater for testing 
procedures.
Refer to Service – electronic controls for 
testing procedures.
CAUTION – Do not eliminate or bypass limit thermostat. Use only B.O.M. replacement part #23717.0003.
42311 071310