Bunn Single TF DBC (with Smart Funnel) Owner's Manual
Page 8
INITIAL SETUP
CAUTION – The brewer must be disconnected from the power source throughout the initial setup, except when
specified in the instructions.
1. Insert an empty funnel into the funnel rails of the brew sta-
tion.
2. Place an empty server under the funnel.
3. Connect the brewer to the power source. Water will begin
flowing into the tank and stop when the tank is filled to its
capacity. Display will show PLEASE WAIT...TANK FILLING
until tank is filled with water.
4. Wait approximately 20 mins for the water in the tank to
heat to the proper temperature on 120V/208V machines.
(Wait approximately 45 mins on 120V machines). Display
will show READY TO BREW...WATER TEMP: XXX˚ when
tank is at operating temperature.
NOTE: Brew water temperature is factory set at 205° F (96.1°
C). Refer to TEMPERATURE SELECTION below should the
water temperature need to be increased or decreased. When
brew water temperature is changed, ready temperature
should be increased or decreased accordingly.
5. Place a small vessel beneath the faucet and open the faucet
handle. Release it when you hear the tank refilling.
6. Water volumes have been preset at the factory. Refer
to adjustments for the Set Brew Volumes section of the
Programming Manual on the Bunn-O-Matic website, at
www.bunn.com should the volume need to be increased
or decreased.
7. The brewer is now ready for use in accordance with the coffee brewing instructions.
TEMPERATURE SELECTION
SET TEMP - Range: 185˚F (85˚C) to 205˚F (96˚C)
This function allows the operator to set the brew water temperature in the tank. It also sets the hot water
faucet dispense temperature.
Procedure to set brew temperature:
1. Press and hold upper right hidden switch until the display reads UNITS. Release switch. Continue to press
and release switch until the display reads SET TEMP.
2. To adjust the brew temperature, press (-) to decrease or (+) to increase the brew temperature.
3. When finished, press and release DONE to save the new setting, exit the SET TEMP function and advance to
the next function screen, SET READY. Another alternative is to press and release the ON/OFF switch (either
on DUAL brewers) located on the front switch panel to exit the SET TEMP function and return to the MAIN
SCREEN.
SET TEMP: XXX°
(-) DONE (+)
35879.2 031512