PROGRAMMING THE DISPENSER
Remove the lower splash guard assembly to access the digital programming module with LCD display.
Press the Down Arrow key to inter the programming menu.
Use the Up and Down Arrow keys to scroll through the menu screens.
Select Exit to leave the programming function and return to normal operations.
NOTE 1: Flashing menu items indicate which selection is active.
NOTE 2: Values shown below are the factory default values for English units.
NOTE 3: Values in [X - X] are the Min. and Max. for that function.
TANK TEMP XXX
AMBIENT UNIT
TANK TEMP XXX
CABINET TEMP XX
 
L DISPENSE RATIO
(-)  35:1  (+)
SET LF TUBE SIZE
1/8    EXIT   3/16
R DISPENSE RATIO
(-)  35:1  (+)
SET RT TUBE SIZE
1/8    EXIT   3/16
FLAVOR GUARD ?
NO    EXIT   YES
 
MENU SCREEN 
 ACTION 
   DESCRIPTION
LF TASTE OK ?
NO    EXIT   YES
FIND  LF  TARGET
PULL     DISPENSE
RT TASTE OK ?
NO    EXIT   YES
 FIND  RT  TARGET
PULL     DISPENSE
If NO - go to LF DISP VOLUME menu.
Use the Down Arrow Key to enter 
Programming Functions
Use the Down Arrow Key to enter 
Programming Functions
Use  the  (+)  or  (-)  buttons  to 
adjust the Mix Ratio
Select tube size.
Use  the  (+)  or  (-)  buttons  to 
adjust the Mix Ratio
Select tube size.
Select (YES) to activate.        Select 
(NO) to deactivate.
Select (YES) or (NO)
Place  a  16  Oz.  (500  mL)  cup 
under the Left dispense tip, then 
activate the Left dispenser
Select (YES) or (NO)
Place  a  16  Oz.  (500  mL)  cup 
under  the  Right  dispense 
tip,  then  activate  the  Right 
dispenser
Normal Display for LCA models, (No Chiller)
Normal Display for LCC models, (with Chiller)
 
Enter the desired Mix Ratio for the concentrate 
used in the Left dispenser. [20:1 - 100:1]
Enter  Pump  Tube  Size  to  be  used  in  the  Left 
metering pump, (see Tube Selection Chart)
Enter the desired Mix Ratio for the concentrate 
used in the Right dispenser. [20:1 - 100:1]
Enter Pump Tube Size to be used in the Right 
metering pump, (see Tube Selection Chart)
Select Yes, if you are ready to calibrate the Flavor 
Guard sensor. Select NO, if you do not wish to 
use this feature, (see Flavor Guard)
Select YES, if you have dispensed several cups 
and are satisfied with the Left dispenser flavor. 
Select NO, if you have not run taste test.
Calibrates  the  Left  FlavorGard™  sensor  to  the 
current MixProfile. The dispenser will shut OFF 
automatically when finished.
Select YES, if you have dispensed several cups 
and are satisfied with the Right dispenser flavor. 
Select NO, if you have not run taste test.
Calibrates the Right FlavorGard™ sensor to the 
current MixProfile. The dispenser will shut OFF 
automatically when finished.
34766 042304