Bunn CW TC Owner's Manual

Page of 17
Page 17
TROUBLESHOOTING (cont.)
PROBLEM
Spitting or excessive steaming 
Dripping from sprayhead
Brew cycle starts when ON/
LOWER Switch is turned on.
Weak beverage
Dry coffee grounds remain in 
the funnel
PROBABLE CAUSE
1. Lime Build-up
1. Syphon System
Auxiliary brew start switch on 
TWINS inadvertently activated.
1. Filter Type
2. Coffee Grind
3. Sprayhead
4. Funnel Loading
5. Water Temperature
1. Funnel Loading
2. Sprayhead
REMEDY
(A) Use deliming spring.
(B) Clean sprayhead. (Page 11)
The brewer must be level or 
slightly lower in front to syphon 
properly.
Move objects away from brewer.
BUNN®  paper filters must be used 
for proper extraction.
A fine or drip grind must be used 
for proper extraction.
A clean spray-head must be used 
for proper extraction.
The BUNN® paper filter must be 
centered in the funnel and the 
bed of ground leveled by gentle 
shaking.
Place an empty funnel on an empty 
dispenser beneath the sprayhead. 
Initiate a brew cycle and check the 
water temperature immediately 
below the sprayhead with a ther-
mometer. The reading should not 
be less than 195°F (76°C). Adjust 
the control thermostat to increase 
the water temperature. Replace if 
necessary.
The BUNN® paper filter must be 
centered in the funnel and the 
bed of grounds leveled by gently 
shaking.
A clean spray-head must be used 
for proper extraction.