Bunn CWT 15-APS Instruction Manual

Page of 17
Page 9
P1241
TWINS
TWINS
These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi 
(138 and 620 kPa) from a 
1
2
" or larger supply line.  A shut-off valve should be installed in the line before the 
brewer.  Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345  
kPa) .  The water inlet fitting is 
3
8
" flare.
1.  Remove six screws securing rear utility cover (if 
equipped). FIG 9-1
2.  Remove cap from the flared fitting on the bottom 
of the center tube assembly.
3.  Flush the water line and securely attach it to the 
flare  fitting  on  the  center  tube  assembly.  FIG 
9-2
4.  Turn on the water supply.
5.  Re-install rear utility cover. FIG 9-3
6.  On models with faucet, place an empty vessel 
beneath the faucet and lift the handle until water 
is dispensed.
P1241
P1241
FIG 9-3
FIG 9-2
FIG 9-1
PLUMBING REQUIREMENTS-EARLY TWINS
41721 111308