Bosch Appliances Network Card D9210B User Manual

Page of 28
D9210B
Installation
D9210B Operation and Installation Guide
© 2002 Bosch Security Systems
Page 19
32206G
3.2.10
Setting the Dipswitch and Tagging the Unit
The D9412 panel supports up to eight door controllers using all eight address settings. The D7412 supports up to two
door controllers using the first two address settings. Each D9210B uses one of eight addresses. Addresses can not be
duplicated
. Because the D9210B is always supervised, two D9210B modules having the same address will not function
and SDI failures will occur.
Fill out the Program Record Sheet. Be sure the program record sheet for this door controller contains the area
assignment, address assignment and control center assignment.
Technical
Tip
Whenever possible, be consistent when numbering doors, control centers, and areas. This will help when
programming a system with more than one door. (Example: Assign Door 1 to Area 1 and Control Center 1.)
The D9210B dipswitch with factory default settings (all ON) is shown in Figure
4. Table 8 shows the serial device reporting address settings for each door
controller. Table 8 also shows dipswitch settings for Test and Fail modes.
Figure 4: D9210B DIP Switch
(Factory Settings)
Door Controller Address
Fail
Mode
1
2
3
4
5*
6*
Serial Device
Control Center Display
Central Station
Modem IIIa
2
D9210 #1
SDI #33
ON
ON
ON
---
---
---
D9210 #2
SDI #34
OFF
ON
ON
---
---
---
D9210 #3
SDI #35
ON
OFF
ON
---
---
---
D9210 #4
SDI #36
OFF
OFF
ON
---
---
---
D9210 #5
SDI #37
ON
ON
OFF
---
---
---
D9210 #6
SDI #38
OFF
ON
OFF
---
---
---
D9210 #7
SDI #39
ON
OFF
OFF
---
---
---
D9210 #8
SDI #40
OFF
OFF
OFF
---
---
---
SDI Fail Mode
SDI Fail – Door Unlocked
---
---
---
ON
---
---
SDI Fail – Door Locked
---
---
---
OFF
---
---
* Switches 5 and 6 must stay in the “ON” position
Table 8: D9210B Dipswitch Settings