Bradley Brand Furniture COMBI5500 User Manual

Page of 6
17" Chase-Mounted Five-Sided Stainless Steel combination Unit
Installation Instructions
COMBI5500
5
Bradley Corporation • 215-329 Rev. J; EN 04-732C
6/28/04
VALVE MOUNTING
PLATE
(159-292)
1/2"-13 THREADED  STUD
   0"-4" WALL (109-039)
   4"-8" WALL (109-040)
   8"-12" WALL (109-048)
WASHER
(142-002AM)
NUT
(110-119)
MOUNTING
CHANNEL
(140-558)
Figure 2
Installation Instructions
continued . . .
Step 2: Mounting Unit to Wall
NOTE:  Refer to Figure 2 when mounting unit. Unit is shown without valves and filler for clarity.
1. Insert six 1/2"-13 threaded studs (supplied by installer) into the back of the unit and screw in
approximately 1/2".
2. Connect the 1-1/2" flush valve supply pipe (supplied by installer) to the 1-1/2" NPT inlet half
coupling located on the back of the fixture.
3. Sliding studs and pipes through the wall openings, position the fixture in place (top of integral
toilet seat is 15" above finished floor).
4. Secure the fixture to the wall using anchor brackets, washers, and nuts provided. 
NOTE: All fasteners must be securely tightened to approximately 30 ft./lbs.