Westinghouse WGR050LP076 Installation Instruction

Page of 60
16 
 
 
                                                                                  WHL-001 REV. 12.17.14 
PERFORMANCE SPECIFICATIONS FOR HIGH EFFICIENCY WATER HEATER MODELS
 
BTUH 
Efficiency 
Temperature Rise in Degrees Fahrenheit 
(°F) 
40 
50 
60 
70 
80 
90 
100 
110 
120 
130 
140 
(°C) 
22
 
28
 
33
 
39
 
44
 
50
 
56
 
61
 
67
 
72
 
78
 
     76,000  
97% 
GPH 
231 
187 
158 
135 
119 
107 
97 
86 
79 
73 
69 
LPH 
874 
708 
598 
511 
450 
405 
367 
326 
299 
276 
261 
Table 2 
– Recovery on rating plate is based at 97% thermal efficiency at 70
o
 Fahrenheit rise, as required by ANSI
 
PART 4 – HEATER PIPING 
 
Failure to follow the instructions in this section WILL VOID the warranty and may result in property damage, serious injury, or death. 
 
 
 
DO NOT pipe this water heater with black iron, galvanized steel, steel, or lead pipe. Doing so will result in premature product failure and 
property damage, and WILL VOID the product warranty. 
 
 
Do not apply heat to the Hot or Cold water heater connections. If sweat connections are used, sweat tubing to the adapter before fitting 
adapter to the water connections on the heater. Any heat applied to the water heater connections will permanently damage the dip tube 
and/or heat traps. Damages due to improper installation practices ARE NOT covered by warranty. 
A. GENERAL PIPING INFORMATION 
 
Use two wrenches when tightening water piping at heater. Use one wrench to prevent the heater return or supply line from turning. 
Failure to prevent piping connections from turning could cause damage to heater components. 
 
 
The heater control module uses temperature sensors to provide both high limit protection and modulating temperature control. The 
control module also provides low water protection by sensing the water level in the tank. Some codes/jurisdictions may require 
additional external controls. 
 
NOTICE
 
Installing the Optional High Output Cold Water Dip Tube 
– For longer hot water draw, remove the factory installed dip tube from the 
cold water inlet and replace with the Optional High Output Cold Water Dip Tube. This can be done by hand. 
 
 
 
Never use dielectric unions or galvanized steel fittings when connecting to a stainless steel storage tank or heater. Use only copper or 
brass fittings. Teflon thread sealant must be used on all connections.