Westinghouse WGR050LP076 Installation Instruction

Page of 60
55 
 
 
                                                                                  WHL-001 REV. 12.17.14 
PART 12 - MAINTENANCE 
 
In unusually dirty or dusty conditions, care must be taken to keep water heater cabinet door in place at all times. Failure to do so VOIDS 
WARRANTY! 
 
 
Allowing the water heater to operate with a dirty combustion chamber will hurt operation. Failure to clean the heat exchanger as needed 
by the installation location could result in water heater failure, property damage, personal injury, or death. Such product failures ARE 
NOT covered under warranty. 
 
 
Hydrogen gas can build up in a hot water system served by this water heater that has not been used for a long period of time (generally 
two weeks or more). When opening a hot water faucet in a system that has been out of use for a time, keep all ignition sources 
(electrical appliances, open flame, etc.) away from the faucet. If hydrogen is present, there will be a sound of air escaping as water 
begins to flow. Allow the water to run for a few minutes to dissipate built up hydrogen from the system. Failure to follow these 
instructions can result in property damage, personal injury, or death. 
 
The water heater requires minimal periodic maintenance under normal conditions. However, in unusually dirty or dusty conditions, 
periodic vacuuming of the cover to maintain visibility of the display and indicators is recommended. 
 
Periodic maintenance should be performed once a year by a qualified service technician to assure that all the equipment is operating 
safely and efficiently. The owner should make necessary arrangements with a qualified heating contractor for periodic maintenance of 
the heater. Installer must also inform the owner that the lack of proper care and maintenance of the heater may result in a hazardous 
condition. 
 
NOTICE
 
It is extremely important that whenever work is performed on the plumbing system that either: 
 
The water heater is powered off, or, 
 
The water heater is valved off and isolated from the plumbing system. 
Failure to take these measures could result in a dry-firing condition. 
 
 
The water heater must be full of water and the system fully purged BEFORE powering the water heater. Performing any work in the 
plumbing system without either powering off the water heater or isolating the water heater through the use of shut-off valves could 
result in a condition referred to as “dry-firing”.  Dry-firing the water heater will damage the heat exchanger, and could result in property 
damage, serious personal injury, or death. Such damages ARE NOT covered by water heater warranty. 
 
INSPECTION ACTIVITIES 
DATE LAST COMPLETED 
PIPING 
1
st
 YEAR 
2
nd
 YEAR 
3
rd
 YEAR 
4
th
 YEAR* 
Near heater piping 
Check heater and system piping for any sign of leakage; 
make sure they are properly supported. 
 
 
 
 
Vent 
Check condition of all vent pipes and joints. Ensure the 
vent piping terminations are free of obstructions and 
blockages. 
 
 
 
 
Gas 
Check Gas piping, test for leaks and signs of aging. Make 
sure all pipes are properly supported. 
 
 
 
 
SYSTEM 
Visual 
Do a full visual inspection of all system components. 
 
 
 
 
Functional 
Test all functions of the system (Heat, Safeties) 
 
 
 
 
Temperatures 
Verify safe settings on heater or Anti-Scald Valve 
 
 
 
 
Temperatures 
Verify programmed temperature settings 
 
 
 
 
ELECTRICAL 
Connections 
Check wire connections. Make sure they are tight. 
 
 
 
 
Smoke and CO 
detector 
Verify devices are installed and working properly. Change 
batteries if necessary. 
 
 
 
 
Circuit Breakers 
Check to see that the circuit breaker is clearly labeled. 
Exercise circuit breaker. 
 
 
 
 
CHAMBER/BURNER 
Combustion Chamber 
Check burner tube and combustion chamber coils. Clean 
according to maintenance section of manual. Vacuum 
combustion chamber. Replace any gaskets that show 
signs of damage.