Westinghouse CSA (Canada) WHC6500E CSA MODEL Owner's Manual

Page of 76
36 
TROUBLESHOOTING
PROBLEM
POTENTIAL CAUSE
SOLUTION
Generator suddenly stops 
running.
1. 
Generator is out of fuel.
1. 
Check fuel level (see page 21). Add fuel if 
necessary.
2. 
The low oil shutdown switch 
has stopped the engine. 
2. 
Check oil level and add oil if necessary (see pages 
27 and 28.
3. 
Too much load
3. 
Restart the generator and reduce the load.
4. 
If trying 1-3 above does 
not solve the problem, the 
cause might be a fault in the 
generator.
4. 
Take the generator to your nearest authorized 
service dealer.
Engine runs erratic; does 
not hold a steady RPM.
1. 
Choke was left in the ON 
position.
1. 
Move choke to the OFF position (see pages 23 
and 24).
2. 
Dirty air filter
2. 
Clean the air filter (see pages 28-30).
3. 
Applied loads may be cycling 
on and off
3. 
As applied loads cycle, changes in engine speed 
may occur; this is a normal condition.
4. 
If trying 1-3 above does not 
solve the problem, the cause 
might be a fault in the generator
4. 
Take the generator to your nearest authorized 
service dealer.