Wegener Communications 6420 User Manual

Page of 135
 
 
iPump 6420 User’s Manual
 
www.wegener.com 
800070-01 Rev B 
Chapter 2, Page 28 
Connector 
Designation 
(Options shown 
in 
red
Type 
Pin #  Signal Description 
 
 
 
 
SERIAL M&C 
9-pin D female jack
 
DCD (internally pulled to +5V) 
 
 
RxD (data output) 
 
 
TxD (data input) 
 
 
DTR (not connected) 
 
 5 
GND 
 
 
DSR (internally pulled to +5V) 
 
 
RTS (not connected) 
 
 
CTS (internally pulled to +5V) 
 
 9 
RI 
(internally pulled to +5V, with weak 
current limiting)
 
 
 
 
 
PIO INPUT 
15-pin D male jack 
PIO #1 In 
 
 
PIO #2 In 
 
 
PIO #3 In 
 
 
PIO #4 In 
 
 
PIO #5 In 
 
 
PIO #6 In 
 
 
PIO #7 In 
 
 8 
Ground 
 
 
PIO #1 Return 
 
 
10 
PIO #2 Return 
 
 
11 
PIO #3 Return 
 
 
12 
PIO #4 Return 
 
 
13 
PIO #5 Return 
 
 
14 
PIO #6 Return 
 
 
15 
PIO #7 Return 
 
 
 
 
ALARM 
15-pin D male jack 
Ground 
 
 
RxD (spare data output) 
 
 
TxD (spare data input) 
 
 4 
Ground 
 
 5 
Ground 
 
 
Cue Relay #1:  Common contact 
 
 7 
Alarm 
(COM closes here on alarm or 
when power is off)
 
 
 8 
OK 
(COM closes here when OK)
 
 
 9 
Ground 
 
 10 
Ground 
 
 11 
Ground 
 
 12 
Ground 
 
 
13 
Cue Relay #1:  N.C. contact 
 
 
14 
Cue Relay #1:  N.O. contact 
 
 15 
COM