10. Move to Program Number; select and edit as necessary.  Use ‘*’ to use the first 
Program available 
11. Move to Tag Site; select and edit as necessary.  Site ‘15’ is the do-not-use choice. 
12. If any changes you wish to keep, move to Done and select 
Check/set audio port settings: 
1.  Start or return to the LCD Home screen is reached (see subsection 2.5.1). 
2.  Move to Unit Setup same level; select that 
3.  Move to Decoder Setup; select that 
4.  Select the audio output, 1, 2, or 3 (Aux) under Decoder Number 
5.  Move to Decoder Setup; select and edit as necessary.  Set to “Follow Tune” if the 
DVB Program assigned in the RF setup is acceptable; set to “Program” to set the 
DVB Program; set to “Off” if not using that Audio Port. 
6.  Move back up to Decoder Setup; then move to Audio Setup; select that 
7.  Select the audio output, 1, 2, or 3 (Aux) under Decoder Number 
8.  Move to Audio Lang Setting; select and edit that.  Use ‘***’ to use the first-available 
audio stream in the Program (OK if only one audio!). 
9.  Repeat as necessary for multiple audio ouptuts 
Check/set LAN and/or WAN Ethernet port settings: 
1.  Start or return to the LCD Home screen is reached (see subsection 2.5.1). 
2.  Move to Unit Setup same level; select that 
3.  Move to Decoder Setup; select that 
4.  Move to IP Setup; select that 
5.  Move to LAN IP Settings; select that 
6.  Move to LAN Addressing Mode; select and edit to be either “Static” or “DHCP”.  If 
“DHCP, you are done with this port. 
7.  If “Static”, move to LAN Static IP Addr; select and edit 
8.  If “Static”, move to LAN Static Netmask; select and edit 
9.  If “Static”, move to LAN Static Gateway; select and edit 
10. If the WAN port is to be checked and set, follow similar steps, but substitute ‘WAN’ 
for ‘LAN’ in instructions 
Check/set Terminal port settings: 
1.  Start or return to the LCD Home screen is reached (see subsection 2.5.1). 
2.  Move to Unit Setup same level; select that 
3.  Move to Serial Port Setup; select that 
4.  Move to Device Assigment; the default is “Terminal”.  If not set there, select and 
edit, if you wish to use the Serial M&C port for monitor and control. 
5.  Move to Term Baud; select and edit the baud rate needed.