Westinghouse FG7TC 95.1% AFUE Two-Stage Technical Manual

Page of 8
i SEER: Energy efficient brushless DC (ECM) motor gives
up to 1 SEER point efficiency gain in cooling.
100% fired and tested: All units and each component
are tested on the manufacturing line.
Best packaging in the industry: Unique corner post
design assures product will arrive to the homeowner dent
free.
30 second blower delay: At start-up assures a warm
duct temperature at furnace start-up. Adjustable blower
off settings (60, 90, 120 and 180 seconds).
30 second post purge:  Increases  life  of  heat
exchanger.
Hot surface igniter:  Innovative  application  of  a
silicon  nitride  type  igniter.  Utilizes  proven  Smartlite
®
technology.
Color coded wire harness:  Designed  to  fit  the
components, all with quick-connect fittings for ease of
service and replacement.
Flexible category IV venting system:  May  be
vertically or horizontally vented using either a one-pipe
or two-pipe system for maximum flexibility in installation.
High Static Blowers:  All  models  equipped  with  high
static blowers.
Low Boy Height: Easy to apply in low ceiling applications,
works well with taller high SEER coils, easier to handle
and install.
Tubular primary heat exchanger:  Heavy  gauge
aluminized  steel  heat  exchanger  and  stainless  steel
secondary heat exchanger assures a long life.
90 second fixed cooling cycle blower-off delay (TDR): 
Increases  cooling  performance  when  matched  with  a
NORDYNE coil.
Variable speed blower kit: Upgradable to full variable
speed with kit.
LP convertible: Simple burner orifice and regulator spring
change for ease of convertibility.
Diagnostic lights for easy troubleshooting without 
counting flashes:
Dedicated light for flame signal strength
and 2 lights in combination to indicate all other fault codes
with easy to recognize states without counting flashes.
Incorporates integrated control board:  With
connections for electronic air cleaner and humidifier.
Two piece door design: Enhances furnace appearance
and uses captured screws to prevent losing door screws.
Blower Compartment: Sealed door to reduce air leakage
and insulated for ultra quiet operation.
Sealed Vestibule: Reduces burner and inducer sound
levels.
2 Stage Inducer: Optimizes efficiency on first stage heat
and reduces sound levels.
Induced Draft - 95.1 AFUE
Input 60,000 - 120,000 Btuh
FG7T (C and L Series)
Two Stage, Fixed Speed ECM, 
High Efficiency Upflow/Horizontal 
and Downflow Gas Furnaces
The high efficiency upflow gas furnace may be installed free
standing in a utility room, basement, or enclosed in an alcove
or closet. Upflow/horizontal units come ready for upflow or
horizontal application. The extended flush jacket provides a
pleasing “appliance appearance.” Design certified by CSA
for application in Canada and the United States.
FEATURES and BENEFITS
TECHNICAL
SPECIFICATIONS
Smartlite
®