Appendix A.  Library Specifications
121
• We recommend using active SCSI terminators on fast single-ended SCSI busses. The 
active terminator helps maintain a high degree of signal integrity and improves 
noise immunity.
• A minus sign (-) next to the signal indicates an active low signal.
• All passive terminators use a 220
Ω pull-up resistor and 330Ω pull-down resistor for 
each signal. Resistor tolerances in the terminator network are 
±5%, or less. Use 
resistors with 
±1% tolerance for improved noise margins.
25
SR/+RST
59
-RST/-RST
26
SR/+MSG
60
-MSG/-MSG
27
SR/+SEL
61
-SEL/-SEL
28
SR/+C/D
62
-C/D/-C/D
29
SR/+REQ
63
-REQ/-REQ
30
SR/+I/O
64
-I/O/-I/O
31
SR/+DB8
65
-DB8/-DB8
32
SR/+DB9
66
-DB9/-DB9
33
SR/+DB10
67
-DB10/-DB10
34
SR/+DB11
68
-DB11/-DB11
Pin
Signal
Pin