UltraViolet Devices Hygeaire Air Disinfection User Manual

Page of 12
9
TROUBLESHOOTING
CAUTION: Always disconnect power to the fixture, before performing any service.
IMPORTANT: This fixture is to be serviced ONLY by qualified, and appropriately licensed, personnel.
Table 1 - Troubleshooting
!
Use personal protection equipment, such as gloves; long sleeves with no gaps between cuffs
and gloves, and ultraviolet resistant face shield, if troubleshooting 
Hygeaire
®
.
Problem Possible 
Cause 
Corrective 
Action
No electrical power… 
Verify that the purifier is connected to a live power source.
Power connections, to fixture,
Verify power connections to fixture are fully engaged.
loose or disconnected… 
Lamp(s) not installed… 
Install lamp(s).
Germicidal lamp not 
Confirm connection of lamp and lamp holder,  make sure
properly seated…
connection is tight and lamp holder is making full contact 
with lamp.
Germicidal lamp faulty…
Swap suspect lamp, with lamp known to be good. If 
suspect lamp does not operate, replace lamp.
Ballast not functioning…
Locate ballast and replace.
Interlock Switch open…
Confirm louver panel is closed and secured. 
Interlock Switch faulty…
Replace Interlock Switch.
Fixture not operating.
Germicidal lamp 
not operating.
TECHNICAL SPECIFICATIONS
Table 2 Technical Specifications
MODEL
LIND 24-EVO
LIND 24-EVO-2PM
Length:
24"
24"
Dimensions:
Width:
4
1
/
2
"
9"
Height:
7-
7
/
8
"
7-
7
/
8
"
Volts:c
120v
220-240v
120v
220-240v
Electrical:
Amps (Max):
.42A
.23A
.83A
.45A
Frequency:
50/60Hz
50/60Hz
50/60Hz
50/60Hz
Total Ultraviolet Output:c
8.5 Watts
17 Watts
c
Ultraviolet output at 254 nm at 100 hours and 80° F (approximate).
d
120v 50/60Hz and 220-240v 50/60Hz units are standard - specify when ordering. Consult factory 
with other specific power requirements.