StorageTek Host Software Component 6 User Manual

Page of 718
Chapter 4. Utility Functions   317
1st ed., 6/30/04 - 312579601
 
SLSCNTL 
the primary control data set. A primary control data set is required.
SLSCNTL2 
the secondary control data set. This statement is used only if you have configured 
and initiated a secondary control data set for your installation. A secondary control  
data set is optional, but highly recommended. 
SLSSTBY
the standby control data set. This statement is used only if you have configured and 
initiated a standby control data set for your installation. SLSIN input to the utility in 
the form of control cards.
Invoking the Set Utility 
The easiest way to run utilities is to execute the ACS UTIL exec by entering the following 
command:
EXEC ACS UTIL SET 
Execution of the statement results in the ACSUTIL SLKJCL file: 
ACSUTIL SLKJCL File 
To execute the utility: 
 1. Delete the lines in the template that are not required, or leave the comment indicator 
(*) in column one. 
 2. Remove the comment indicator from the desired lines. 
 3. Specify values for the desired parameters.
 4. Delete the parameters that are not desired. 
 5. Enter the command ‘‘FILE.’’ 
The job file is then submitted to the ACS service machine for execution.
/JOB jobname SLUADMIN 
/PARM MIXED 
/FILE SLSPRINT DEV PRNT CLASS A 
/FILE SLSCNTL  DEV <500>   DSN <dsname> 
/FILE SLSCNTL2 DEV <501>   DSN <dsname> 
/FILE SLSSTBY  DEV <vaddr> DSN <dsname> 
/FILE SLSIN    * 
* SET COMPRFX(cmdhex) 
Set