StorageTek Host Software Component 6 User Manual

Page of 718
334   VM/HSC 6.0 System Programmer’s Guide
1st ed., 6/30/04 - 312579601
 
JCL/Parameter File Syntax 
Syntax for JCL (SCP) and parameter file (CMS) definitions differs as follows: 
SLSCNTL 
For SCP: 
/FILE SLSCNTL DEV vaddr DSN control.set.name 
For CMS: 
SLSCNTL vaddr DSN control.set.name 
where: 
vaddr 
virtual address of the disk containing the CDS. For SCP, this is the address of the 
disk defined for the ACS service machine. For CMS, this is the address of the disk 
linked to the machine executing the SLUVOLR EXEC. 
control.set.name 
name of the control data set. 
SLSPRINT
 For SCP: 
/FILE SLSPRINT DEV PRNT CLASS C 
For CMS: 
SLSPRINT PRINTER | DISK fn ft fm
Table 18.  SLSVA Effect on Volume Report
HSC State: 
SLSVA Specified:
SLSVA Not Specified: 
Active 
Use VOLATTRs pointed to 
by SLSVA. 
*
*  If VOLATTRs have been defined, media prefix characters are displayed before the ‘‘Media’’ field
if the media types reported by the LMU and the VOLATTR statements do not agree. If VOLATTRs
are not present, media prefix characters are not displayed. 
Use VOLATTRs used by the 
HSC. 
 
Inactive
 Use VOLATTRs pointed to 
by SLSVA.
The HSC generates an error 
message saying that SLSVA 
is missing and incorrect data 
may be reported. In addition, 
no prefix characters appear 
before the ‘‘Media’’ field on 
the report to identify media 
type discrepancies.
Volume Report